Daikin FDXS25EAVMB [32/223] Outdoor unit

Daikin FDXS25EAVMB [32/223] Outdoor unit
Printed Circuit Board Connector Wiring Diagram SiBE07-724_B
22 Printed Circuit Board Connector Wiring Diagram
1.2 Outdoor Unit
1.2.1 RK(X)S25/35E2V1B
Connectors and
Other Parts
PCB (1): Filter PCB
PCB (2): Main PCB
1) S11 Connector for main PCB
2) HL1, HN1, S Connector for terminal board
3) E Terminal for earth
4) HC1, HC2
HL2, HN2
Connector for main PCB
5) HR1 Connector for reactor
6) FU3 Fuse (20 A, 250 V)
7) V2, V3 Varistor
1) S10 Connector for filter PCB
2) S20 Connector for electronic expansion valve coil
3) S30 Connector for compressor
4) S40 Connector for overload protector
5) S70 Connector for fan motor
6) S80 Connector for four way valve coil
7) S90 Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
8) HC3, HC4
HL3, HN3
Connector for filter PCB
9) HR2 Connector for reactor
10)FU1, FU2 Fuse (3.15 A, 250 V)
11)LED A LED for service monitor (green)
12)V1 Varistor
13)J5 Jumper for improvement of defrost performance
Refer to page 205 for detail.
14)J8 Jumper for facility setting
Refer to page 204 for detail.
15)SW1 Forced cooling operation ON/OFF switch

Содержание