106
() Dedicated connection kit: EKEPHTH.
() Dedicated connection kit: EKEPHTH () EKHYPART can be used if you have a tank in which you can insert
the thermistor.
() EKHYPART can needs to be used if you have a tank in which you can’t insert a thermistor.
() Only  sensor can be connected: indoor OR outdoor sensor.
() Additional relays to allow bivalent control in combination with external room thermostat
are eld supply.
W
all mounted Floor standing integrated tank
Floor standing
integrated bi-zone
Floor standing
integrated ECH
2
O
Solar kit HT
incl. pump station
Mounting stand
H/O
(White)
Reversible
(White)
H/O
(White + grey)
Reversible
(White + Grey)
H/O
(White)
H/O
(White)
ETVH16S18DA6V (G) ETVX16S18DA6V (G) ETVZ16S18DA6V ETSH(B)16P30DA
ETVH16S18DA9W (G) ETVX16S18DA9W (G) ETVZ16S18DA9W ETSH(B)16P50DA
ETBH16DA6V ETBX16DA6V ETVH16S23DA6V (G) ETVX16S23DA6V (G) ETVZ16S23DA6V ETSX(B)16P30DA
Type Description Material name ETBH16DA9W ETBX16DA9W ETVH16S23DA9W (G) ETVX16S23DA9W (G) ETVZ16S23DA9W ETSX(B)16P50DA EKSRPS4A
EKMST1/2
Outdoor unit
EPRADAV/W
EPRADAV/W
EPRADAV/W
Controllers
Wired room thermostat BRCHHDA*
Wired digital thermostat EKWCTRDIV
Wired analog thermostat EKWCTRANV
Valve actuator EKWCVATRV
Wired underoor heating base station EKWUFHTAV
LAN Adapters + APP
BRPA
BRPA
W-LAN adapter T.B.C.
Heat pump convector
Floor standing FWXV--AT V
Wall mounted FWXT--ATV
Concealed FWXM--ATV
Domestic hot water tank
Stainless steel tank
EKHWS(U)DV
EKHWS(U)DV
EKHWS(U)DV
EKHWS(U)DV
EKHWS(U)DV
Polypropylene tank
EKHWPB
(1) (1)
EKHWPB
(2) (2)
EKHWPPB
(1) (1)
EKHWPPB
(2) (2)
Third party tank kit
EKHYPART
(3) (3)
EKHYPART
(4) (4)
Options
Bi-zone kit BZKAV
Remote indoor sensor KRCS-
(5) (5) (5) (5) (5)
Remote outdoor sensor EKRSCA
(5) (5) (5) (5) (5)
PC USB cable EKPCCAB
Universal centarlized controller EKCC-W
Digital I/O PCB EKRPHBAA
(6) (6) (6) (6) (6)
Demand PCB EKRPAHTA
Freeze protection valve AFVALVE
Conversion kit H/O => reversible
EKHBCONV
EKHVCONV
Dedicated options for ECH
O unit
Backup heater switch box EKBUHSWB
Backup heater kW EKBUBC
Backup heater kW EKBUBC
Backup heater kW EKBUC
Room thermostat EHS
Mixer module EHS
Optional outdoor sensor EKRSC
Gateway for Apps EHS
Hydraulic separator 
Heat insulation for HWC 
Pump group with mixer module 
Pump group without mixer module 
Connection kit for MK 
Dirt seperator SAS 
Dirt separator SAS 
Biv Connector Kit 
DB connector Kit 
Terminal connection kit 
Connector external heater 