Daikin EKPS076207 [38/216] Daikin altherma 3 h f

Daikin EKPS075867 [38/216] Daikin altherma 3 h f
38
EPGA-DV
EAVH-DV
Daikin Altherma 3 H F
Floor standing air to water heat pump for heating
andhot water; ideal for low energy houses
Integrated stainless steel domestic hot water tank of  or  l
PCB board and hydraulic components are located in the front
for easy access
Small installation footprint of  x  mm
Integrated back-up heater choice of  or  kW
Outdoor unit extracts heat from the outdoor air, even at - °C
EAVH-D6V(G)/D9W(G) + EPGA-DV3
EAVH-DVG
Eciency data EAVH + EPGA
16S18D6V(G)/
D9W(G) + 11DV
16S23D6V(G)/
D9W(G) + 11DV
16S18D6V(G)/
D9W(G) + 14DV
16S23D6V(G)/
D9W(G) + 14DV
16S18D6V(G)/
D9W(G) + 16DV
16S23D6V(G)/
D9W(G) + 16DV
Heating capacity Nom. kW . () / . () . () / . () . () / . ()
Power input Heating Nom. kW . () / . () . () / . () . () / . ()
COP . () / . () . () / . () . () / . ()
Space heating
Average
climate water
outlet  °C
General SCOP . . .
ŋs (Seasonal space
heating eciency)
%   
Seasonal space heating e. class
A++
Average
climate water
outlet  °C
General SCOP . . .
ŋs (Seasonal space
heating eciency)
%   
Seasonal space heating e. class
A++ A+++
Domestic hot water heating
General Declared load prole L XL L XL L XL
Average
climate
ŋwh (water heating eciency)
%      
Water heating energy eciency class
A
Indoor Unit EAVH
16S18D6V(G)/
D9W(G)
16S23D6V(G)/
D9W(G)
16S18D6V(G)/
D9W(G)
16S23D6V(G)/
D9W(G)
16S18D6V(G)/
D9W(G)
16S23D6V(G)/
D9W(G)
Casing Colour White + Black
Material Resin / Sheet metal
Dimensions Unit Height x Width x Depth mm , x  x  , x  x  , x  x  , x  x  , x  x  , x  x 
Weight Unit kg      
Tank Water volume l      
Maximum water temperature °C 
Maximum water pressure bar 
Corrosion protection Pickling
Operation range Heating Ambient Min.~Max. °C ~
Water side Min.~Max. °C ~
Domestic
hot water
Ambient Min.~Max. °CDB ~
Water side Max. °C 
Sound power level Nom. dBA 
Sound pressure level
Nom. dBA 
Outdoor Unit EPGA 11DV 14DV 16DV
Dimensions Unit
Height x Width x Depth
mm , x , x 
Weight Unit kg 
Compressor Quantity
Type Hermetically sealed scroll compressor
Operation range Cooling Min.~Max. °CDB ~
Domestic hot water Min.~Max. °CDB -~
Refrigerant Type R-
GWP .
Charge kg .
Charge
TCO
Eq
.
Control Expansion valve
Sound power level Heating Nom. dBA  
Cooling Nom. dBA
Sound pressure level Heating Nom. dBA   
Cooling Nom. dBA 
Power supply Name/Phase/Frequency/Voltage Hz/V V/N~//
Current Recommended fuses A 
()
Cooling Ta  °C - LWE  °C (DT =  °C); heating Ta DB/WB  °C/ °C - LWC  °C (DT =  °C) () Cooling Ta  °C - LWE  °C ( DT =  °C); heating Ta DB/WB  °C/ °C - LWC  °C ( DT =  °C ).
60 °C
BRCHHDW
up to
A
+
A
B
C
D
E
F
G
A
+++
A
++
A
+
A
B
C
D
E
F
G
011-1W0319 -> 324