Eciency data EHSH + ERGA 04P30D2 + 04DV 08P30D2 + 06DV 08P50D + 06DV 08P30D2 + 08DV 08P50D + 08DV
Heating capacity Nom. kW . () / . () . () / . () . () / . ()
Power input Heating Nom. kW . () / . () . () / . () . () / . ()
COP . () / . () . () / . () . () / . ()
Space heating
Average climate
water outlet
 °C
General SCOP . .
ŋs (Seasonal
space heating
eciency)
%  
Seasonal space heating e. class
A++
Average climate
water outlet
 °C
General SCOP . . .
ŋs (Seasonal
space heating
eciency)
%  
Seasonal space heating e. class
A+++
Domestic hot water
heating
General Declared load prole L XL L XL
Average
climate
ŋwh (water heating eciency) %    
Water heating energy eciency class A+ A A+ A
Indoor Unit EHSH 04P30D2 08P30D2 08P50D 08P30D2 08P50D
Casing Colour Trac white (RAL) / Dark grey (RAL)
Material Impact resistant polypropylene
Dimensions Unit Height x Width x Depth mm , x  x  , x  x  , x  x  , x  x 
Weight Unit kg    
Tank Water volume l    
Maximum water temperature °C 
Operation range Heating Ambient Min.~Max. °C -~
Water side Min.~Max. °C ~
Domestic
hot water
Ambient Min.~Max. °CDB -~
Water side Min.~Max. °C ~
Sound power level Nom. dBA 
Outdoor Unit ERGA 04DV 06DV 08DV
Dimensions Unit
Height x Width x Depth
mm  x  x 
Weight Unit kg .
Compressor Quantity
Type Hermetically sealed swing compressor
Operation range Cooling Min.~Max. °CDB .~.
Domestic hot water Min.~Max. °CDB - ~
Refrigerant Type R-
GWP .
Charge kg .
Charge
TCO
Eq
.
Control Expansion valve
Sound power level Heating Nom. dBA   
Cooling Nom. dBA  
Sound pressure
level
Heating Nom. dBA   
Cooling Nom. dBA  
Power supply Name/Phase/Frequency/Voltage Hz/V V/N~//
Current Recommended fuses A 
() Cooling Ta  °C - LWE  °C (DT =  °C); heating Ta DB/WB  °C/ °C - LWC  °C (DT =  °C) () Cooling Ta  °C - LWE  °C ( DT =  °C); heating Ta DB/WB  °C/ °C - LWC  °C ( DT =  °C ).
ERGA-DV EHSH-D
Daikin Altherma 3 R ECH
2
O
Floor standing air to water heat pump for heating
andhot water with thermal solar support
Integrated solar unit, oering top comfort in
heating and hot water
Maximum use of renewable energy: uses heat pump
technology for heating and solar support for space heating
and domestic hot water production
Fresh water principle: hygienic water, with no need for
thermallegionelladisinfection
Maintenance-free tank: no corrosion, anode,scale or lime
deposits,and no loss of water through safety valve
Solar support of domestic hot water with pressureless
(drain-back) solar system
Heat loss is reduced to a minimum thanks to the high
quality insulation
App control possible for managing heating, hot water
and cooling operation
Outdoor unit extracts heat from the outdoor air, even at - °C
Possible to connect to photovoltaïc solar panels to provide
energy for your heat pump
EHSH-D(2) + ERGA-DV
65 °C
-W
-W 
A
+
A
B
C
D
E
F
G
A
+++
A
++
A
+
A
B
C
D
E
F
G
up to up to