4.Warning and Cautions
Warning and Cautions
renoitidnoC riA citsemoD
4
Electrical shock hazard
•
•
•
•
Plug into a mating, grounded 3 prong outlet.
• Do not remove the ground prong from the power supply cord.
Do not use a plug adapter, extension cord, surge protector, or multi-outlet adapter
Failure to follow these instructions can result in injury, fire, or electrical shock.
WARNING
1. DO NOT cut or remove the grounding prong on the attached power supply cord. Doing so may cause sparks or fire,
and voids all warranties. For safety purposes the air conditioner must be properly grounded.
2. To avoid a fire hazard or possible electric shock, DO NOT use an adapter plug, extension cord,surge protectors, or
multi-outlet adapters with the air conditioner.
3. The power supply cord is equipped with a 3-prong plug which mates with a standard 115 volt wall outlet to minimize
the possibility of electrical shock from this air conditioner.
4. The power supply cord includes a leakage current detection interrupter device (LCDI). A RESET and TEST button are
on the plug case. The device should be tested on a periodic basis by pressing the TEST button and then the RESET
button while it is plugged into the wall outlet. If the TEST button does not trip or the RESET will not stay engaged,
do not use the air conditioner and contact a qualified service technician.
5. Have the wall outlet and circuit inspected by a qualified electrician to ensure that the wall outlet is properly grounded.
6. If there is a 2-prong wall outlet present and not a 3-prong wall outlet, it is the responsibility of the user to have it
replaced with a properly grounded 3-prong outlet.
7.
The air conditioner should always be plugged into a dedicated electrical outlet which has a voltage rating that matches
the serial label on the side of the air conditioner.
8. The electrical ratings for your air conditioner are listed on the Model/Serial Number label. The Model/Serial Number
label is located on the side of the air conditioner cabinet, or behind the front grille.
9. Specific electrical requirements are listed in the chart below. Follow the requirements for the type of plug on the
power supply cord.
ELECTRICAL REQUIREMENTS
Recommended grounding method
Power supply cord
This air conditioner must be grounded. This air conditioner is equipped with a power supply cord that has a 3 prong
grounding plug. The power supply cord must be plugged into a mating, grounded 3 prong outlet, and grounded in
accordance with all local codes and ordinances. If a mating outlet is not available, it is the customer’s responsibility to
contact a qualified electrician and ensure that a properly grounded 3 prong outlet is installed.
This room air conditioner is equipped with an a leakage current detection interrupter ( LCDI) power supply cord required
by UL. This power supply cord contains a current detection device. If the power supply cord is crushed, this device will
detect current leakage and power will be disconnected from the air conditioner. If this power supply cord is damaged, it
cannot be repaired and must be replaced with a cord from the product manufacturer.
Содержание
- Esa406m 1
- Hwe06xcn 1
- Model no 1
- Service manual 1
- Warning 1
- Table of contents 2
- Specification 4
- R e n oitid n o c ri a cits e m o d 5
- Safety and precaution 5
- Warning 5
- Electrical requirements 6
- Power supply cord 6
- Recommended grounding method 6
- Warning 6
- Warning and cautions 6
- Energy saving guide 7
- Installation and accessory parts 8
- R e n oitid n o c ri a cits e m o d 8
- A width 9
- B height 9
- Install top channel 9
- Of the air 9
- Prepare air conditioner for installation 9
- Window installation 9
- Install side curtains 10
- Prepare window for installation 11
- R e n oitid n o c ri a cits e m o d 11
- Completing the installation 12
- Fig 10 12
- Fig 11 12
- Final installation 13
- Domestic air conditioner 14
- Installation and accessory parts 14
- Side curtains 2 side curtain frames 2 remote control 14
- Top channel foam seal side bracket 2 14
- Window lock bracket 3 8 self tapping screws 3 1 wood screws 9 14
- Parts and functions 15
- R e n oitid n o c ri a cits e m o d 15
- R e n oitid n o c ri a cits e m o d 17
- Using the remote control 17
- Prbutton the air conditioner will operate in energy save mode low fan speed and temperature of 72 f you can select any other mode to satisfy your needs ess on off to turn on the air conditioner when you first press the on off 18
- R e n oitid n o c ri a cits e m o d 18
- Abnormity diagnose 19
- Sensor diagnose 19
- System flow chart 21
- Circuit diagram 22
- R e n oitid n o c ri a cits e m o d 22
- Circuit diagram 23
- R e n oitid n o c ri a cits e m o d 21 23
- Wiring diagram 24
- Haier group 25
- Sincere forever 25
- Wang ruofeng 25
Похожие устройства
- Haier HWE06XCN Инструкция по эксплуатации
- Haier HWE08XCN Инструкция по эксплуатации
- Haier HWE10XCN Инструкция по эксплуатации
- Haier HWE12XCN Инструкция по эксплуатации
- Haier HWR05XC9 Инструкция по эксплуатации
- Haier HWR05XC9-L Инструкция по эксплуатации
- Haier HWR05XCJ Инструкция по эксплуатации
- Haier HWR05XC5 Сервис мануал
- Haier HWR05XC5 Инструкция по эксплуатации
- Haier HWF05XC5 Сервис мануал
- Haier HWF05XC5 Инструкция по эксплуатации
- Haier HWF05XC6 Сервис мануал
- Haier HWF05XC6 Инструкция по эксплуатации
- Haier HPU-90CA03T3 Инструкция по эксплуатации
- Haier HWF05XCK Инструкция по эксплуатации
- Haier HWF05XCK-T Инструкция по эксплуатации
- Haier HWF05XCK-L Инструкция по эксплуатации
- Haier HWF05XCK-E Инструкция по эксплуатации
- Haier HPN14XCM Инструкция по эксплуатации
- Alpina P361 Инструкция по эксплуатации