Panasonic CU-HE12NKE [5/110] Specification

Panasonic CU-HE9NKE [5/110] Specification
5
2. Specification
Indoor CS-HE9NKE CS-AE9NKE
Model
Outdoor CU-HE9NKE CU-AE9NKE
Performance Test Condition EUROVENT
Phase, Hz Single, 50
Power Supply
V 230
Min. Mid. Max.
kW 0.85 2.50 3.00
BTU/h 2900 8530 10200
Capacity
kcal/h 730 2150 2580
Running Current A — 2.2 —
Input Power W 170 455 670
Annual Consumption kWh 228
W/W 5.00 5.49 4.48
BTU/hW 17.06 18.75 15.22
EER
kcal/hW 4.29 4.73 3.85
Power Factor % 90
dB-A 39 / 26 / 23
Indoor Noise (H / L / QLo)
Power Level dB 55 / 42 / 39
dB-A 46 / - / -
Cooling
Outdoor Noise (H / L / QLo)
Power Level dB 61 / - / -
kW 0.85 3.20 6.50
BTU/h 2900 10900 22200
Capacity
kcal/h 730 2750 5590
Running Current A — 2.7 —
Input Power W 165 575 1.70k
W/W 5.15 5.57 3.82
BTU/hW 17.58 18.96 13.06
COP
kcal/hW 4.42 4.78 3.29
Power Factor % 93
dB-A 42 / 27 / 24
Indoor Noise (H / L / QLo)
Power Level dB 58 / 43 / 40
dB-A 47 / - / -
Heating
Outdoor Noise (H / L / QLo)
Power Level dB 62 / - / -
Low Temp. : Capacity (kW) / I.Power (W) / COP 4.71 / 1.50k / 3.14
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 3.92 / 1.46k / 2.68
Max Current (A) / Max Input Power (W) 8.0 / 1.72k
Starting Current (A) 2.7
Type Rotary Motor
Motor Type Brushless (4 poles)
Compressor
Output Power W 900

Содержание