Zyxel VES-1616FE-55A [101/318] Dpbo electrical length

Zyxel VES-1616FE-55A [101/318] Dpbo electrical length
Chapter 13 xDSL Port Setup
VES-1616FE-55A User’s Guide
101
An example is shown next. VDSL Line 1 and ADSL Line 2 are in the same binder. Crosstalk
occurs when the ADSL signal flows from CO (B) and is near to CO (A)s ONU (Optical
Network Unit) location. Besides, higher Line 1 PSD causes higher interference to the Line 2.
CPE (B) receives signal with higher attenuation. With DPBO enabled on the CO (A), it
decreases the PSD level and reduces the crosstalk impact on other service lines.
Figure 54 DPBO Resolves Downstream Far-End Crosstalk
13.4.9 DPBO Electrical Length
The distance between a cabinet and the central office is an important parameter of DPBO
settings as we mentioned in the Section 13.4.8 on page 100. The electrical length is used
instead of the real physical distance according to G.997.1 format. Depending on the cable type
the line used and physical line length, you can calculate the electrical length (in dB). For
example, the distance is 1 kilometer and you use 24 AWG cable type, the electrical length 20.5
dB is suggested to used.
The following table displays the calculation from a real length to an electrical length.
VDSL
CPE (B)
Line1 (150m)
Line2 (600m)
No-DPBO
DPBO
ADSL
CO (A)
ADSL
CPE (A)
VDSL
CO (B)
Table 21 Real Length to Electrical Length
CABLE TYPE REAL LENGTH TO ELECTRICAL LENGTH A B C
22 AWG =16.2*(cable length in kilometer) 0 0 0
24 AWG =20.5*(cable length in kilometer) 0 1 0
26 AWG =25.8*(cable length in kilometer) 0 1.0039065 -0.0039065