Chapter 14 xDSL Profiles Setup
VES-1616FE-55A User’s Guide
120
Figure 66 Alarm Profile
The following table describes the labels in this screen.
Table 29 Alarm Profile
LABEL DESCRIPTION
Name This field is read-only if you click Modify to edit a port profile. Type a name to
identify the alarm profile (you cannot change the name of the DEFVAL profile).
You can use up to 31 ASCII characters; spaces are not allowed.
Add Click Add to save your changes to the VES-1616FE-55A’s volatile memory. The
VES-1616FE-55A loses these changes if it is turned off or loses power, so use
the Config Save link on the navigation panel to save your changes to the non-
volatile memory when you are done configuring.
Cancel Click Cancel to start configuring the screen again.
Threshold Specify limits for the individual performance counters. The VES-1616FE-55A
sends an alarm trap and generates a syslog entry when one of these thresholds
is exceeded. A value of 0 disables the alarm threshold.
15 Min LOF This field sets the limit for the number of Loss Of Frame seconds that are
permitted to occur within 15 minutes.
15 Min LOS This field sets the limit for the number of Loss Of Signal seconds that are
permitted to occur within 15 minutes.
15 Min LOL This field sets limit for the number of Loss Of Link seconds that are permitted to
occur within 15 minutes.
15 Min LPR This field sets the limit for the number of Loss of Power (on the XTUR) seconds
that are permitted to occur within 15 minutes.
15 Min ES This field sets the limit for the number of Errored Seconds that are permitted to
occur within 15 minutes.
15 Min SESL This field sets the limit for the number of Severely Errored seconds that are
permitted to occur within 15 minutes.
15 Min UASL This field sets the limit for the number of UnAvailable seconds that are permitted
to occur within 15 minutes.