Chapter 45 Alarm
VES-1616FE-55A User’s Guide
253
Figure 149 Alarm Event Setup
The following table describes the labels in this screen.
Table 112 Alarm Event Setup
LABEL DESCRIPTION
Index This field displays the index number of the alarm in the list. Click this link to
specify the severity level of an alarm(s) and where the system is to send the
alarm(s). See Section 45.5.1 on page 254.
Alarm This field displays the alarm category to which the alarm belongs.
dsl represents Digital Subscriber Line (DSL) alarms.
enet represents Ethernet alarms.
eqpt represents equipment alarms.
sys represents system alarms.
Condition Code This field displays the condition code number for the specific alarm message.
Condition This field displays a text description for the condition under which the alarm
applies.
Facility This field displays the log facility (Local 1~ Local 7) on the syslog server where
the system is to log this alarm. This is for alarms that send alarms to a syslog
server.
SNMP This field displays “V” if the system is to send this alarm to an SNMP server. It
displays “-“ if the system does not send this alarm to an SNMP server.
Syslog This field displays “V” if the system is to send this alarm to a syslog server. It
displays “-“ if the system does not send this alarm to a syslog server.
Severity This field displays the alarm severity level (critical, major, minor or info).
Clearable This displays “V” if the alarm clear command removes the alarm from the
system. It displays “-“if the alarm clear command does not remove the alarm
from the system.