Zyxel VES-1616FE-55A [219/318] Supported mibs

Zyxel VES-1616FE-55A [219/318] Supported mibs
Chapter 37 Access Control
VES-1616FE-55A User’s Guide
219
37.3.1 Supported MIBs
MIBs let administrators collect statistics and monitor status and performance. The VES-
1616FE-55A supports the following MIBs:
VDSL Line MIB(RFC-3728)
MIB II IF MIB
SNMP MIB II (RFC-1215)
RFC 3728 VDSL MIB
The VES-1616FE-55A can also respond with specific data from the DSLAM private MIBs:
•dslam.mib
37.3.2 SNMP Traps
The VES-1616FE-55A can send the following SNMP traps to an SNMP manager when an
event occurs. XTUC refers to the downstream channel (for traffic going from the VES-
1616FE-55A to the subscriber). XTUR refers to the upstream channel (for traffic coming from
the subscriber to the VES-1616FE-55A).
Table 85 SNMPv2 Traps
TRAP NAME DESCRIPTION
coldStart This trap is sent when the VES-1616FE-55A is turned on.
warmStart This trap is sent when the VES-1616FE-55A restarts.
linkDown This trap is sent when the Ethernet link is down. Enterprise specific
(xdslXtucLos) traps are sent when an xDSL link is down.
linkUp This trap is sent when the Ethernet or xDSL link comes up.
reboot This trap is sent when the system is going to reboot. The variable is the
reason for the system reboot.
overheat This trap is sent when the system is overheated. The variable is the
current system temperature in Celsius.
overheatOver This trap is sent when the system is no longer overheated. The
variable is the current system temperature in Celsius.
voltageOutOfRange This trap is sent when the voltage of the system is out of the normal
range. The variable is the current voltage of the system in volts.
voltageNormal This trap is sent when the voltage of the system is back within the
normal range. The variable is the current voltage of the system in volts.
extAlarmInputTrigger This trap is sent when there is an external alarm input.
extAlarmInputRelease This trap is sent when the external alarm input stops.
thermalSensorFailure This trap is sent when the thermal sensor fails.
vdslPerfLofsThreshNotificatio
n
The number of times a Loss Of Frame has occurred within 15 minutes
for the XTUC has reached the threshold.
vdslPerfLossThreshNotificati
on
The number of times a Loss Of Signal has occurred within 15 minutes
for the XTUC has reached the threshold.
vdslPerfLprsThreshNotificatio
n
The number of times a Loss Of Power has occurred within 15 minutes
for the XTUC has reached the threshold.
vdslPerfLolsThreshNotificatio
n
The number of times a Loss Of Link has occurred within 15 minutes for
the XTUC has reached the threshold.