Chapter 7 System Information
VES-1616FE-55A User’s Guide
81
Enable Select this check box to turn the hardware monitor on or clear it to turn the
hardware monitor off.
Temperature Unit Select C to display all temperature measurements in degrees Celsius. Select F
to display all temperature measurements in degrees Fahrenheit.
Temperature- C Each temperature sensor can detect and report the temperature. Temperature
sensor 1 is near the DSL chipset. Temperature sensor 2 is near the central
processing unit. Temperature sensor 3 is at the hardware monitor chip.
Current This shows the current temperature at this sensor.
MAX This field displays the maximum temperature measured at this sensor.
MIN This field displays the minimum temperature measured at this sensor.
Average This field displays the average temperature measured at this sensor.
Threshold (Low) This field displays the lowest temperature limit at this sensor.
Threshold (Hi) This field displays the highest temperature limit at this sensor.
Status This field displays Normal for temperatures below the threshold and Over for
those above.
Voltage The power supply for each voltage has a sensor that can detect and report the
voltage.
Current This is the current voltage reading.
MAX This field displays the maximum voltage measured at this point.
MIN This field displays the minimum voltage measured at this point.
Average This field displays the average voltage measured at this sensor.
Threshold (Low) This field displays the lowest voltage limit at this sensor.
Threshold (Hi) This field displays the highest voltage limit at this sensor.
Status Normal indicates that the voltage is within an acceptable operating range at this
point; otherwise Abnormal is displayed.
External Alarm
Status
Name
Apply
The VES-1616FE-55A is able to detect alarm input from other equipment
connected to the ALARM connector.
The Status column displays Normal when no alarm input has been detected
from other equipment. It displays Abnormal when alarm input has been
detected from other equipment.
Use the Name column to configure a title for each external alarm for
identification purposes. Use up to 31 characters.
Click Apply to save the name changes to the VES-1616FE-55A’s volatile
memory. The VES-1616FE-55A loses these changes if it is turned off or loses
power, so use the Config Save link on the navigation panel to save your
changes to the non-volatile memory when you are done configuring.
Use this section below to configure the hardware monitor threshold settings.
New threshold
Apply
Configure new threshold settings in the fields below and click Apply to use
them.
Index This field is a sequential value.
Temperature- C (Hi) Use these fields to configure the highest temperature limit at each sensor.
Temperature- C (Lo) Use these fields to configure the lowest temperature limit at each sensor.
Volt. (Hi) Use these fields to configure the highest voltage limit at each sensor.
Volt. (Lo) Use these fields to configure the lowest voltage limit at each sensor.
Table 12 System Info (continued)
LABEL DESCRIPTION