Chapter 50 Troubleshooting
VES-1616FE-55A User’s Guide
277
Figure 162 Example: Resetting the Switch: Via the Console Port
The switch is now reinitialized with a default configuration file including the default password
of “1234”.
Bootbase Version: V1.05 | 02/15/2008 13:46:24
FLASH: AMD 32M
Hardware Version:
Serial Number:
RAM: Size = 196608 Kbytes
DRAM POST: Testing:196512K
OK
ZyNOS Version: V3.53(BHL.0)b2 | 03/10/2008 15:01:47
Press any key to enter debug mode within 3 seconds.
....................
Enter Debug Mode
sysname> atlc
Starting XMODEM upload (CRC mode)....
CCCCCCCCCCCCCCCC
Total 393216 bytes received.
Erasing..
................................................................
OK
sysname> atgo