Autel MaxiCheck PRO Руководство пользователя онлайн [73/76] 171295

Autel MaxiCheck PRO Руководство пользователя онлайн [73/76] 171295
71
4. The tool may display information during and after the test. The
information varies by vehicle.
Figure 8.19
5. When the test is finished, there may be three results displaying
on the screen.
The test is finished successfully.
The test is stopped by the user.
The test did not finish.
In the first condition, the tool will display an information screen as
The operation was performed correctly. Put the vehicle on a
vehicle lift and check that the rear wheels are locked. Check
that the 'Electric parking brake on' message is display on the
control panel and that the LED illuminates on the control
panel.
In the second condition, the tool will display an information screen
as Operation of the actuator test was stopped by the user.
Press Cancel' to go back to the list of possible operations.
In the third condition, the tool will display an information screen as
The actuator test did not finish operating. Please perform the
following check: Read the faults to resolve any possible faults
relating to the electric motor or to the cables.
IMPORTANT: Make sure that the components to be tested are
not physically damaged and are well assembled.
Apply electric parking brake
Listen to the noise of the
Electric motor!