Reference Address Data Type Description
30001 0x0000 1 word CH0 DI Count Value Hi-Byte
30002 0x0001 1 word CH0 DI Count Value Lo-Byte
30003 0x0002 1 word CH1 DI Count Value Hi-Byte
30004 0x0003 1 word CH1 DI Count Value Lo-Byte
30005 0x0004 1 word CH2 DI Count Value Hi-Byte
30006 0x0005 1 word CH2 DI Count Value Lo-Byte
30007 0x0006 1 word CH3 DI Count Value Hi-Byte
30008 0x0007 1 word CH3 DI Count Value Lo-Byte
30009 0x0008 1 word CH4 DI Count Value Hi-Byte
30010 0x0009 1 word CH4 DI Count Value Lo-Byte
30011 0x000A 1 word CH5 DI Count Value Hi-Byte
30012 0x000B 1 word CH5 DI Count Value Lo-Byte
30013 0x000C 1 word CH0 DO Totoal Relay Count Value Hi-Byte
30014 0x000D 1 word CH0 DO Totoal Relay Count Value Lo-Byte
30015 0x000E 1 word CH1 DO Totoal Relay Count Value Hi-Byte
30016 0x000F 1 word CH1 DO Totoal Relay Count Value Lo-Byte
30017 0x0010 1 word CH2 DO Totoal Relay Count Value Hi-Byte
30018 0x0011 1 word CH2 DO Totoal Relay Count Value Lo-Byte
30019 0x0012 1 word CH3 DO Totoal Relay Count Value Hi-Byte
30020 0x0013 1 word CH3 DO Totoal Relay Count Value Lo-Byte
30021 0x0014 1 word CH4 DO Totoal Relay Count Value Hi-Byte
30022 0x0015 1 word CH4 DO Totoal Relay Count Value Lo-Byte
30023 0x0016 1 word CH5 DO Totoal Relay Count Value Hi-Byte
30024 0x0017 1 word CH5 DO Totoal Relay Count Value Lo-Byte
30025 0x0018 1 word CH0 DO Last Reset Time for Current Relay Count
Sec Value
30026 0x0019 1 word CH0 DO Last Reset Time for Current Relay Count
Min Value
30027 0x001A 1 word CH0 DO Last Reset Time for Current Relay Count
Hour Value
30028 0x001B 1 word CH0 DO Last Reset Time for Current Relay Count
Mday Value
30029 0x001C 1 word CH0 DO Last Reset Time for Current Relay Count
Month Value
30030 0x001D 1 word CH0 DO Last Reset Time for Current Relay Count
Year Value
30031 0x001E 1 word CH1 DO Last Reset Time for Current Relay Count
Sec Value
30032 0x001F 1 word CH1 DO Last Reset Time for Current Relay Count
Min Value
30033 0x0020 1 word CH1 DO Last Reset Time for Current Relay Count
Hour Value
30034 0x0021 1 word CH1DO Last Reset Time for Current Relay Count
Mday Value
30035 0x0022 1 word CH1 DO Last Reset Time for Current Relay Count
Month Value
30036 0x0023 1 word CH1 DO Last Reset Time for Current Relay Count
Year Value
30037 0x0024 1 word CH2 DO Last Reset Time for Current Relay Count
Sec Value