Intel rms25cb080 [12/60] Intel integrated raid module rms25pb0x0 and rms25cb0x0
![Intel rms25cb080 [12/60] Intel integrated raid module rms25pb0x0 and rms25cb0x0](/views2/1219999/page12/bgc.png)
2 Intel® Integrated RAID Module RMS25PB0x0 and RMS25CB0x0 Hardware User’s Guide
inhibit airflow. The point-to-point SATA architecture eliminates difficulties created by the
legacy ATA master-slave architecture, while maintaining compatibility with existing
ATA firmware.
Intel
®
Integrated RAID Module RMS25PB0x0 and
RMS25CB0x0
The Intel
®
Integrated RAID Module RMS25PB080, RMS25PB040, RMS25CB080 and
RMS25CB040 are intelligent RAID adapter with an integrated LSI SAS2208 dual-core
RAID-On-Chip chipset, providing both a SAS controller and RAID engine. With 1GB
RAM built onto the board and four independent ports (RMS25PB040 and RMS25CB040)
or eight independent ports (RMS25PB080 and RMS25CB080) supporting 6Gb/s and
3Gb/s SAS data transfers using one or two SFF-8087 mini multi-lane connectors, the
controllers support up to 128 enterprise-class SAS or SATA devices.
Intel
®
Integrated RAID Module RMS25PB080 and RMS25PB040 are custom low-profile
RAID adapters and the PCI Express* connector fits into an x8 or x16 PCI Express* slot
capable of performance up to 8 GT/s per lane.
Intel
®
Integrated RAID Module RMS25CB080 and RMS25CB040 are custom board-to-
board PCI Express* 3.0 compliant interface RAID adapters and the PCI Express*
connector fits into a 80 pin connector capable of performance up to 8 GT/s per lane.
The RAID modules are designed to fit various Intel
®
Server Boards and systems. For the
most up-to-date support list, see the Compatibility section under the link for these Intel
®
Integrated RAID Modules at http://www.intel.com/p/en_US/support/server
.
Note: The modules will support PCI Express* Revision 3.0 at post launch.
Protocol Support
Each port on the SAS controllers supports SAS devices, SATA devices, or both using SSP,
SMP, STP, and SATA II as follows:
• Serial SCSI Protocol (SSP) to enable communication with other SAS devices.
• SATA II Protocol to enable communication with other SATA devices.
• SATA III Protocol to enable communication with other SATA III devices.
• Serial Management Protocol (SMP) to share topology management information
with expanders.
• Serial Tunneling Protocol (STP) support for SATA II through expander interfaces.
Operating System Support
• Windows Server 2008 R2*, Windows 7*, Windows Server 2003*, Windows Vista*
Содержание
- Audience 3
- Organization 3
- Preface 3
- Related publication 4
- Chapter 1 overview 1 5
- Chapter 2 inte 5
- Chapter 3 inte 5
- Integrated raid module rms25pb0x0 and rms25cb0x0 char acteristics 15 5
- Integrated raid module rms25pb0x0 and rms25cb0x0 hard ware installation 7 5
- Preface iii 5
- Table of contents 5
- Appendix a drive roaming and drive migration install 7 6
- Appendix b installation assembly safety instructions 9 6
- Appendix c regulatory and certification information 9 6
- List of figures 7
- List of tables 9
- Benefits of sas and sata 11
- Overview 11
- Integrated raid module rms25pb0x0 and rms25cb0x0 12
- Intel integrated raid module rms25pb0x0 and rms25cb0x0 12
- Operating system support 12
- Protocol support 12
- Usability 13
- Redundancy and error handling 14
- Beep codes 15
- Online capacity expansion and raid level migration rules 15
- Sas sata features 15
- Installing the inte 17
- Installing the intel integrated raid module rms25pb0x0 17
- Integrated raid module rms25pb0x0 17
- Integrated raid module rms25pb0x0 and rms25cb0x0 hardware installation 17
- Intel integrated raid module rms25pb0x0 and rms25cb0x0 hardware installation 17
- Requirements 17
- Installing the inte 20
- Installing the intel integrated raid module rms25cb0x0 20
- Integrated raid module rms25cb0x0 20
- Configuring the raid module 23
- Replacing a module 23
- Resolving a config mismatch 23
- Figure 7 rms25pb0x0 card layout 25
- Integrated raid module rms25pb0x0 and rms25cb0x0 characteristics 25
- Intel integrated raid module rms25pb0x0 and rms25cb0x0 characteristics 25
- Table 1 rms25pb0x0 jumper description 25
- Figure 8 rms25cb0x0 card layout 26
- Table 2 rms25cb0x0 jumper description 26
- Figure 9 inte 27
- Integrated raid module rms25pb0x0 hardware block diagram 27
- Lsi sas2208 27
- Pci e 3 x8 pci e slot 27
- Lsi sas2208 28
- Lsi sas2208 roc 28
- Major components 28
- Boot strap rom seeprom 29
- Flash rom 29
- Nvsram 29
- Sdram cache 29
- Audible alarm 30
- Diagnostic components 30
- Internal connector 31
- Led placement and function 31
- Sas sata connector pin out 31
- Sas sata connectors 31
- Table 3 sff8087 internal connector with one sgpio connector pin out 32
- Bbu rmfbu connector pin out 33
- Note the raid controller in this document doesn t ship with sas sata cables users can separately order the sas sata cable accessory kit as needed please see the tested operating system list for available cable accessory kits at http www intel com p en_us support server 33
- Table 4 bbu rmfbu connector pin out 33
- Integrated raid module rms25pb080 and rms25pb040 must be installed into a standard x8 or larger pci express slot that complies with the pci express specification revision 3 the controller is pci express 1 and 2 compatible and is backward compatible with x8 or larger slots that are wired with x1 x2 and x4 pci express lanes 34
- Note the modules will support pci express revision 3 at post launch 34
- Pci interface 34
- Host board interface 35
- Table 5 host board interface connector pin out 36
- Integrated raid module rms25cb040 and rms25cb080 dimensions 37
- Mechanical overview 37
- The following figures display the inte 37
- Figure 15 mechanical drawing for inte 38
- Integrated raid module rms25cb0x0 38
- Intel integrated raid module rms25pb0x0 and rms25cb0x0 hardware user s guide 38
- Led headers 38
- There is one 2 pin header present on the rms25pb080 and rms25pb040 board and this header is used for connecting the external led which indicates activity on any of the connected hdds 38
- Figure 16 led header 39
- Table 6 led headers pin out 39
- Table 7 technical specifications 39
- Technical specifications 39
- Array performance features 40
- Table 8 array performance features 40
- Fault tolerance 41
- Table 9 fault tolerance features 41
- Actual power consumption 42
- All power is supplied to the adapter via the pci express 3 v and 12v rail necessary voltages are provided by onboard switching regulator circuitry operating off of 12v and 3 v rails 42
- Electrical characteristics 42
- Note 12v is used in the charging circuitry for the battery pack on the optional bbu remote card if the bbu remote card is cable connected the following power consumption figures apply 1 during trickle charging of the battery pack n a no trickle charge for li ion 2 during fast charging of the battery pack 250ma rise in 12v current 42
- State 1 during bbu fast charge 42
- State 2 during initialization of all raid 5 logical drives simultaneously 42
- State 3 while sitting idle at the dos prompt 42
- Supply voltage 12v 8 from pci edge connector only 42
- Supply voltage 3 v 9 from pci edge connector only 42
- Table 10 actual power consumption table 42
- The following states determine the typical current consumption of the board 42
- The maximum board temperature is limited by the lsi sas2208 roc processor since it uses the most power and will be the hottest component on the board 42
- Thermal and atmospheric characteristics 42
- Operating certifications 43
- Safety characteristics 43
- Sas expander support 43
- Support for hard disk drive devices 43
- Supported device technology 43
- Enclosure management support 44
- Hierarchy 44
- Integrated raid module rms25pb080 rms25pb040 rms25cb080 and rms25cb040 support the internal sas sideband signal sff 8485 sgpio enclosure management interface 44
- One or more arrays are associated and given a raid level this process creates a virtual drive and provides an option to initialize the virtual drive 44
- One or more physical drives are selected and associated as an array 44
- Raid firmware is based on the concept of associating physical drives in arrays and then creating a virtual drive from that array that includes a functional raid level to create a virtual drive and present it to the host operating system the raid firmware typically follows these steps 44
- Raid functionality and features 44
- Raid physical drive status 44
- Selected non hard drive devices are supported for use with this module for information on support for non hard drive devices see this raid module s tested hardware and operating system list 44
- Support for non hard disk drive devices 44
- Table 11 raid physical drive status 44
- The fundamental purpose of a raid system is to present a usable data storage medium virtual drive with some level of redundancy to a host operating system the inte 44
- The inte 44
- The raid firmware presents the virtual drive to the operating system 44
- Only drives that comply with the sas and sata specification extensions are supported 45
- Raid controller drive limitations 45
- Raid virtual drive status 45
- Table 12 raid virtual drive status 45
- Appendix a drive roaming and drive migration install 47
- Drive roaming 47
- Drive migration 48
- Appendix b installation assembly safety instructions 49
- English 51
- Read all caution and safety statements in this document before performing any of the instructions see also inte 51
- Server boards and server chassis safety information on the resource cd and or at http www intel com support motherboards server sb cs 010770 htm 51
- Deutsch 52
- Français 53
- Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction consultez inte 53
- Server boards and server chassis safety information sur le cd resource cd ou bien rendez vous sur le site http www intel com support motherboards server sb cs 010770 htm 53
- Español 55
- Lea todas las declaraciones de seguridad y precaucion de este documento antes de realizar cualquiera de las instrucciones vea inte 55
- Server boards and server chassis safety information en el cd resource y o en http www intel com support motherboards server sb cs 010770 htm 55
- Italiano 56
- Appendix c regulatory and certification information 59
- Product safety and emc compliance 59
Похожие устройства
- Intel r2208gz4gs9 Инструкция по эксплуатации
- Intel r1304rpssfbn Инструкция по эксплуатации
- Intel r2208gl4gs Инструкция по эксплуатации
- Intel r2224gz4gc4 Инструкция по эксплуатации
- Intel r2216gz4gclx Инструкция по эксплуатации
- Intel r2308gz4gc Инструкция по эксплуатации
- Intel r2224gz4gcsas Инструкция по эксплуатации
- Intel r2312gl4gs Инструкция по эксплуатации
- Intel r2308gl4gs Инструкция по эксплуатации
- Intel r1304gz4gc Инструкция по эксплуатации
- Intel r1208gz4gc Инструкция по эксплуатации
- Intel sr1630gp Инструкция по эксплуатации
- Patriot PT 3555ES Country Инструкция по эксплуатации
- Patriot PT 4555ES Country Инструкция по эксплуатации
- Patriot PT 5555ES Country Инструкция по эксплуатации
- Patriot T 556 Pro Инструкция по эксплуатации
- Patriot РТ 2540 Деталировка
- Patriot РТ 2540 Инструкция по эксплуатации
- Patriot РТ 3045 Imperial Деталировка
- Patriot РТ 3045 Imperial Инструкция по эксплуатации