Replacing fuses
n Park the sweeper and switch off the engine.
n Open the unit cover.
n Replace blown fuses with ones with the same rating.
Note:
If a fuse blows repeatedly, this indicates a fault somewhere in the electrical
system. Please call Customer Service.
Replacing the dust filters
The dust filters should be inspected for damage every 50 operating hours.
A significant build-up of dust at the air outlet from the fan is a sign of a filter
that is not fitted properly or is defective.
n Raise the hopper half way 1.
n Release the catches on the filter box 2.
n Swivel the filter box forwards and lift it off 3.
n Open out the handle, pull it outwards and turn it through 90º (make sure it
engages) 4.
n Remove the filter cartridge 5.
n Insert a new filter cartridge (pins should fit into the holes) 6.
n Turn the handle back to its original position and make sure it locks in
place.
n Mount the filter box and engage the catches.

Содержание

English User Instructions KMR 1250 LPG Replacing fuses Park the sweeper and switch off the engine Open the unit cover Replace blown fuses with ones with the same rating Note If a fuse blows repeatedly this indicates a fault somewhere in the electrical system Please call Customer Service Replacing the dust filters The dust filters should be inspected for damage every 50 operating hours A significant build up of dust at the air outlet from the fan is a sign of a filter that is not fitted properly or is defective Raise the hopper half way 1 Release the catches on the filter box 2 Swivel the filter box forwards and lift it off 3 Open out the handle pull it outwards and turn it through 90 make sure it engages 4 Remove the filter cartridge 5 Insert a new filter cartridge pins should fit into the holes 6 Turn the handle back to its original position and make sure it locks in place Mount the filter box and engage the catches 44