ISA Blizzard 1P RV TB [7/30] Sectioning the electricity supply
![ISA Blizzard 1P RV TB [7/30] Sectioning the electricity supply](/views2/1335874/page7/bg7.png)
7
EN
BLIZZARD
USE AND MAINTENANCE MANUAL
428000396
137
UPRIGHT DISPLAY CABINETS
2.2.3 Sectioning the electricity supply
Before conducting any maintenance work on the equipment or part of it, it is necessary to
section the power supply that powers it.
Danger
Please remember to fully disconnect the equipment from the power supply in the event of maintenance
work during which the operator cannot prevent any accidental closure of the circuit by other people.
2.3 Residual risks
During design the manufacturer examined all the areas or parts at risk. Therefore, all
necessary precautions have been taken to prevent risks to persons and damage
to the equipment as mentioned earlier.
Attention
Periodically check that all safety devices are operating correctly.
Do not remove the fi xed protective devices.
Do not introduce foreign objects or tools into the operational and working area.
Although the equipment is fi tted with the aforementioned safety devices, there are still
some risks that cannot be eliminated, but reduced via corrective actions by the fi nal
integrator and correct operational procedures.
Below is a summary of the remaining risks associated with the equipment during:
- Normal operation
- Adjustments and tweaking
- Maintenance
- Cleaning
2.3.1 Risk of contact with live parts
Risk of breaking or damaging the electrical components of the equipment, with a possible
reduction in safety levels, following a short circuit.
Before connecting the electricity supply, make sure there is no ongoing maintenance work.
Attention
Before making the connection, check that the d/c electricity at the point of installation is no higher than
the value indicated on the protective switches on the fuse box. if it is, the user is responsible for fi tting
the relevant limiting devices.
It is strictly forbidden to conduct any electrical modifi cation, in order to prevent additional unforeseen
hazards and risks.
2.3.2 Fire
Danger
In the event of a fi re, immediately disconnect the master switch from the main power supply line.
Содержание
- Blizzard 1
- Isa s r l 1
- Blizzard 2
- Contents 2
- Notes important notes 4
- Introduction 5
- Manufacturer s contact details 5
- Fixed protective devices 6
- Personnel training 6
- Safety 6
- Safety devices applied 6
- Safety devices present 6
- Although the equipment is fi tted with the aforementioned safety devices there are still some risks that cannot be eliminated but reduced via corrective actions by the fi nal integrator and correct operational procedures 7
- Before conducting any maintenance work on the equipment or part of it it is necessary to section the power supply that powers i 7
- Below is a summary of the remaining risks associated with the equipment during 7
- During design the manufacturer examined all the areas or parts at risk therefore all necessary precautions have been taken to prevent risks to persons and damage to the equipment as mentioned earlier 7
- Normal operation adjustments and tweaking maintenance cleaning 7
- Residual risks 7
- Risk of breaking or damaging the electrical components of the equipment with a possible reduction in safety levels following a short circuit before connecting the electricity supply make sure there is no ongoing maintenance work 7
- Risk of contact with live parts 7
- Sectioning the electricity supply 7
- Circuit faults 8
- Explosive atmosphere 8
- Slipping 8
- Tripping 8
- Warning sign 8
- Refrigerant r290 9
- Waste disposal 10
- Electrical connection 11
- Installation 11
- Installation positioning and ambient conditions 11
- Storage and unpacking 11
- The equipment with or without the packaging should be carefully stored inside warehouses or in areas away from the elements and direct sunlight at a temperature between 0 and 40 c the equipment should only be moved by qualifi ed personnel operating forklift trucks the power of which should be suited to handling the weight of the product during this operation the equipment must be placed on the special pallet supplied 11
- This manual provides information on how to unpack position and connect to the power supply 11
- Unpack the equipment by removing the screws fi xing it to the pallet all packaging materials are recyclable and should be disposed of in accordance with local regulations please destroy plastic bags to prevent them from becoming hazardous to children suffocation 11
- Technical specifications 12
- Blizzard 13
- Technical specifications 13
- Installatio 14
- Aaaaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaaaaaaa 15
- Load limits 15
- Positioning levelling 15
- Adjustable shelves 16
- Blizzard 16
- Kg product 16
- Product grids load limits 16
- Equipment description 17
- Identifi cation 17
- Insulated structure in ecological polyurethane led lighting cooling system at ventilated refrigeration glass door electronic commands panel electrical system on board condensing unit height adjustable feet adjustable shelves 17
- Structure 17
- The equipment consist of a single piece of furniture which contains all the operational devices necessary to make it a professional and effi cient product for its intended use 17
- The equipment consists of 17
- To ensure the operator s safety equipment devices should be kept in constant working order this manual is intended to illustrate the use and maintenance of the equipment the operator has a responsibility and duty to carefully observe its instructions 17
- Control panel 18
- Start up 18
- Blizzard 19
- User interface 19
- Check up 20
- Manual activation of the defrosting cycle 20
- Set button 20
- Accessing and cleaning the condensing unit 21
- Chiller compartment inside cleaning 21
- External cleaning operations 21
- Routine maintenance and regular check 21
- Any work conducted on the on the equipment must involve disconnection from the power socket and in any case none of the protective elements grid casing should be removed by non qualifi ed staff the equipment should not be operated when these protective elements have been removed 22
- Extraordinary 22
- Maintenance 22
- Routine 22
- The equipment manager must check and respect the maintenance schedule in the table below by calling the authorised technical assistance service when indicated 22
- Faults 23
- If the appliance is not working properly or stops working before contacting the customer support centre check the following 23
- Technical assistance 23
- List of alarms on the electronic controlle 24
- Warranty terms and conditions 24
- Attachments 25
- Attachments 1 electrical diagram 412100164000 26
- Blizzard 26
- Attachments 2 electrical diagram 412100165100 27
- Blizzard 27
- Attachments 3 electrical diagram 412100166100 28
- Blizzard 28
- Attachment 4 declaration of conformity 29
- Blizzard 29
- Declaration of conformity 29
- Product 29
- Serial number 29
- Via del lavoro 5 06083 bastia umbra pg 29
- We isa s r l 29
- Pagina 1 30
Похожие устройства
- ISA Blizzard 2P RV TB Инструкция по эксплуатации
- ISA Blizzard 3P RV TB Инструкция по эксплуатации
- ISA Zero T5 SP Инструкция по эксплуатации
- ISA Zero T8 VT SP Инструкция по эксплуатации
- ISA Zero T16 VT SP Инструкция по эксплуатации
- ISA Zero T8 OR SP Инструкция по эксплуатации
- ISA Zero T8 VT SP GEL Инструкция по эксплуатации
- ISA Zero T8 OR SP GEL Инструкция по эксплуатации
- ISA Zero T16 VT SP GEL Инструкция по эксплуатации
- ISA Zero T12 VT SP GEL Инструкция по эксплуатации
- Bras IS-Cream with mixer Инструкция Bras IS-Cream with mixer (англ.)
- Bras IS-Cream with mixer Руководство по установке
- Bras IS-Cream with mixer Каталог оборудования Bras (англ.)
- ISA Zero T5 SP GEL Инструкция по эксплуатации
- La Nordica Sibilla Plus Инструкция по эксплуатации
- La Nordica Sibilla Plus Технический паспорт
- La Nordica Sibilla Plus Декларация о соответствии (англ.)
- La Nordica Sibilla Plus Декларация о соответствии (англ.)
- ISA Zero T12 VT SP Инструкция по эксплуатации
- La Nordica Doroty Инструкция по эксплуатации