Zelmer Aquos ZVC722ST (829.0 ST) [59/60] Disposal

Zelmer Aquos ZVC722ST (829.0 ST) [59/60] Disposal
59
The manufacturer does not accept any liability for any damages
resulting from unintended use or inappropriate handling.
The manufacturer reserves his rights for modifying the product any
time in order to adjust it to law regulations, norms, directives, or due
to construction, trade aesthetic or other reasons, without notifying it
in advance.
2
Place the vacuum cleaner with the “wheels upwards” so
that the upper sloping surface and the handle are rested on
the oor. Insert a at, narrow tool e.g. a screwdriver into the
special slot of the lter lid; pry the fastening with an upward
hand movement (lever principle) which will release the lid
wwlatch while being bent.
3
If the motor lter (9) is dirty, it is possible to rinse the
lter (9) under running water. Remember to dry the above
mentioned lter before reassembly.
4
Insert the new/rinsed motor lter (9), make sure that the
lter edges do not remain outside the outline of the section.
Snap the lter lid shut by rst inserting the lower fastening
and then pressing the fastening so that the upper fastening
clicks into place at the edge of the appliance body.
OUTLET EPA E10 FILTER AND FOAM FILTER III
The EPA E10 outlet lter should be replaced after about 30
hours of operation (6 months) or earlier in case of heavy dirt.
1
Remove the tank from the vacuum cleaner.
2
Place the vacuum cleaner with the “wheels upwards” so
that the upper sloping surface and the handle are rested on
the oor.
3
Slide the slider of the lter cover interlock to the “open”
position and remove the lter lid.
4
Remove the foam lter III (12). Rinse or replace if the lter
becomes dirty. Remember to dry the lter before reassembly.
5
Remove the foam lter III (12) and next remove the
EPA E10 lter by grabbing the handle. Replace with a new
one if the lter becomes dirty.
It is recommended to periodically inspect the condition of the
lter, especially if there was a water overow to the outside of
the vacuum cleaner. In case of detecting damage (a break)
in the lter layer or if the layer is evenly covered with dust,
the lter should be replace with a new one.
6
If the EPA E10 lter is dirty, replace it with a new one or
rinse under running water. Remember to dry the lter before
reassembly.
7
Reinsert the lters, insert the lter lid and press rmly.
8
Slide the slider of the lter cover interlock to the “closed”
position.
Turn the vacuum cleaner to its natural position (on four
wheels).
Disposal
Dispose of packaging in an environmentally-
friendly manner. This appliance is labelled
in accordance with European Directive
2012/19/EU concerning used electrical and
electronic appliances (waste electrical and
electronic equipment WEEE). The guideline
determines the framework for the return and recycling of
used appliances as applicable throughout the EU. Please
ask your specialist retailer about current disposal facilities.