D-Link DGS-1210-52/ME rev.B [181/519] Cable diagnostic port

D-Link DGS-1210-28XS/ME [181/519] Cable diagnostic port
DGS-1210/ME Metro Ethernet Switch CLI Reference Guide
163
Command: show syslog host
Host ID Host IP Address Severity Facility UDP Port Status
--------- ----------------------- ----------- ------------ ------------- -----------
1 1.1.2.1 All Local0 514 Enabled
Total Entries : 1
DGS-1210-28MP/ME:5#
cable diagnostic port
Purpose To determine if there are any errors on the copper cables and the
position where the errors may have occurred.
Syntax
cable diagnostic port [<portlist> | all]
Description
The cable diagnostic port command is used to determine if there
are any errors on the copper cables and the position where the
errors may have occurred.
Cable length is detected as following
range: <50m, 50~80, 80~100, >100m. Deviation is +/-
5 meters,
therefore "No Cable" may be displayed under "Test Result
," when
the cable used is less than 5 m in length. The Fault Distance will
show “No Cable”, whether the fiber is connected to the port or not.
Parameters
<portlist> A port or range of ports to be configured.
all − Specifies all ports on the Switch are to be configured.
Restrictions None.
Example usage:
To determine the copper cables and position of port 3 on the Switch:
DGS-1210-28MP/ME:5# cable diagnostic port 15
Command: cable diagnostic port 15
Perform Cable Diagnostics ...
Port Type Link Status Test Result Cable Length (M)
------- ------- ------------------- ------------------------- ----------------------------
15 GE Link Up OK 4
DGS-1210-28MP/ME:5#
config syslogintimeout
Purpose To configure the system login timeout.
Syntax
config syslogintimeout <integer 3-30>
Description
The config syslogintimeout command is used to
configure the
system login timeout.