Fluke 43B [43/54] Specifications function specifications
![Fluke 43B [43/54] Specifications function specifications](/views2/1005303/page43/bg2b.png)
Specifications
Function Specifications
3
39
Scope
Input Impedance
Input 1 ............................... 1 MΩ // 12 pF (± 2 pF). With BB120: 20 pF ± 3 pF
Input 2 ............................... 1 MΩ // 10 pF (± 2 pF). With BB120: 18 pF ± 3 pF
Horizontal
Time base modes (selectable) ..............................................Normal, Single, Roll
Ranges (selectable within modes)
In Normal................................................................................. 5 s to 20 ns/div
In Single shot............................................................................. 5 s to 1 µs/div
In Roll mode .............................................................................. 60 s to 1 s/div
Time base error..................................................................... < ±(0.4 % + 1 pixel)
Maximum sampling rate
10 ms to 60 s........................................................................................ 5 MS/s
20 ns to 10 ms.................................................................................... 25 MS/s
Trigger source (AUTO, 1/2 AUTO, MANUAL)........................... Input 1 or Input 2
Vertical
Voltage ranges .................................................................5.0 mV/div to 500 V/div
Trace accuracy ±(1 % + 2 pixels)
Bandwidth input 1 (voltage)
excluding test leads or probes.......................................DC to 20 MHz (-3 dB)
with test leads TL24......................................................... DC to 1 MHz (-3 dB)
with 10:1 probe VPS100-R (optional) ............................ DC to 20 MHz (-3 dB)
with shielded test leads STL120 (optional) ................. DC to 12.5 MHz (-3 dB)
DC to 20 MHz (-6 dB)
Lower transition point (AC coupling)........................................... 10 Hz (-3 dB)
Bandwidth input 2 (current)
with Banana-to-BNC adapter...................................................... DC to 15 kHz
Lower transition point (AC coupling)........................................... 10 Hz (-3 dB)
Содержание
- Fluke 43b 1
- Power quality analyzer 1
- Users manual 1
- Placing orders and getting assistance 2
- Chapter title page 3
- Table of contents 3
- Fluke 43b 4
- The following items are included in your fluke 43b kit 5
- Unpacking 5
- Fluke 43b 6
- Safety information read first 6
- Warning 6
- Safety information read first 7
- Warning 7
- Current probe 8
- Fluke 43b 8
- Warning 8
- Chapter 1 9
- Introducing the fluke 43b 9
- Powering the fluke 43b 9
- Fluke 43b 10
- Inputs 11
- Introducing the fluke 43b input 11
- Fluke 43b 12
- Main menu 12
- Introducing the fluke 43b main men 13
- Fluke 43b 14
- Harmonics 14
- Volts amps hertz 14
- Inrush current 15
- Introducing the fluke 43b main men 15
- Sags swells 15
- Transients 15
- Fluke 43b 16
- Time resolution in sags swells and record modes 16
- Introducing the fluke 43b main men 17
- Fluke 43b 18
- Instrument setup 18
- Setting the date 18
- Accept the new time 19
- Adjust the hours 19
- Introducing the fluke 43b instrument setu 19
- Repeat steps 4 and 5 for minutes and seconds 19
- Setting the time 19
- Adjusting the contrast 20
- Fluke 43b 20
- Selecting probes 21
- Fluke 43b 22
- Move to the probe settings for input 2 22
- Users manual 22
- Introducing the fluke 43b instrument setu 23
- Setting up the harmonic and power function 23
- Fluke 43b 24
- Introducing the fluke 43b instrument setu 25
- Selecting a language 25
- Fluke 43b 26
- Using flukeview software 26
- Introducing the fluke 43b using a printe 27
- Using a printer 27
- Fluke 43b 28
- Selecting a printer type 28
- Resetting the fluke 43b 29
- Chapter 2 31
- Cleaning and storage 31
- Cleaning the current probe 31
- Cleaning the fluke 43b 31
- Maintenance 31
- Storing the fluke 43b 31
- Batteries 32
- Charging the batteries 32
- Fluke 43b 32
- Extending battery operation time 33
- Fluke 43b 34
- Replacing the ni mh battery pack 34
- Warning 34
- Fluke 43b 36
- Ordering codes 36
- Replaceable parts 36
- Maintenance ordering codes 37
- Manuals 37
- Fluke 43b 38
- Flukeview does not recognize the fluke 43b 38
- The batteries operate less than four hours 38
- The fluke 43b does not start up 38
- The printer does not print 38
- The screen remains black 38
- Troubleshooting 38
- Chapter 3 39
- Introduction 39
- Specifications 39
- Fluke 43b 40
- Safety specifications 40
- Electrical functions 41
- Function specifications 41
- Specifications function specifications 41
- Fluke 43b 42
- Specifications function specifications 43
- Fluke 43b 44
- Record 45
- Specifications function specifications 45
- Fluke 43b 46
- Miscellaneous 46
- Environmental conditions 47
- Specifications environmental conditions 47
- Disturbance with test leads tl24 in scope mode v ac dc true rms 48
- Disturbance with test leads tl24 or current clamp i400s volts amps hertz resistance capacitance power harmonics 48
- Electromagnetic immunity 48
- Fluke 43b 48
- No visible disturbance 48
- Ranges not specified in tables 2 and 3 may have a disturbance of more than 10 of full scale 48
- Table 1 48
- Table 2 48
- Table 3 48
- The fluke 43b including standard accessories conforms with the eec directive 89 336 for emc immunity as defined by iec1000 4 3 with the addition of the following tables 48
- Users manual 48
- Current probe i400s 49
- Electrical specifications 49
- Electromagnetic compatibility emc 49
- Safety specifications 49
- Fluke 43b 50
- General specifications 50
- Declaration of conformity 51
- Fluke 43b 52
- Limited warranty limitation of liability 52
- Users manual 52
Похожие устройства
- Indesit IWUD 4105 Инструкция по эксплуатации
- Geo-Fennel FL 60 Maxi-Liner 580000 Инструкция по эксплуатации
- Fluke 51 II Инструкция по эксплуатации
- Indesit IWD 5105 Инструкция по эксплуатации
- LG MS-1744WB Инструкция по эксплуатации
- Blue Weld Prestige Plasma 54 Kompressor Инструкция по эксплуатации
- Supra SWM-774 Инструкция по эксплуатации
- Fluke 52 II Инструкция по эксплуатации
- LG MS-1744W Инструкция по эксплуатации
- Indesit WITL 867 Инструкция по эксплуатации
- Geo-Fennel FL 45 HP 520510 Инструкция по эксплуатации
- Supra SWM-770 Инструкция по эксплуатации
- Belkin F9S600 Инструкция по эксплуатации
- Fluke 53 II Инструкция по эксплуатации
- Indesit WISE 10 CSI Инструкция по эксплуатации
- LG MS-1744U Инструкция по эксплуатации
- Bosch PHC 9690 ProSalon Инструкция по эксплуатации
- Geo-Fennel Square Linner II 551000 Инструкция по эксплуатации
- Supra SWM-755 Инструкция по эксплуатации
- LG MS-1744HL Инструкция по эксплуатации