Fluke 43B [50/54] General specifications

Fluke 43B [50/54] General specifications
Fluke 43B
Users Manual
46
Common Mode Voltage: 1000 V ac rms from earth ground, in compliance
with EN61010-1
Input Load Impedance (of host instrument): > 1M in parallel with up to 47
pF
Maximum Non-destructive Current: 1000 A
Duty Cycle: 0.5 A to 400 A continuous
Influence of Adjacent Conductor: < 9.0 mA/A
Influence of Conductor Position in Jaw Opening: ±1.0 % of reading +0.05
A
General Specifications
Output Cable Length: 2.5 m
Maximum Conductor Size: 32 mm
Storage Temperature: -20 °C to 60 °C
Operating Temperature: 0 °C to 50 °C
Relative Humidity: 10 °C to 30 °C: 95 %
30 °C to 40 °C: 75 %
40 °C to 50 °C: 45 %
Temperature Coefficient: 0.01 % x (specified accuracy)/ °C (< 18 °C or > 28
°C)
Altitude: Operating: 2000 m; 2000 m to 4000 m, derate category rating to
1000 V CAT II/600 V CAT III, Non-operating: 12000 m
Dimensions: 150 x 70 x 30 mm
Weight: 114 g

Содержание