Fluke 43B [49/54] Current probe i400s

Fluke 43B [49/54] Current probe i400s
Specifications
Current Probe i400s
3
45
Current Probe i400s
Safety Specifications
Category Rating: CAT III 1000 V and CAT IV 600 V per EN/IEC61010-1,
Pollution Degree 2.
: Tested to US and Canadian standards for compliance to UL 61010-1
and CAN/CSA C22.2 No.61010-2-32-04
: EN 61010-2-32:2002
Electromagnetic Compatibility (EMC)
Acc. to EN 613261, FCC for emission and immunity
Electrical Specifications
Reference Conditions: 23 ± 5 °C, 20 to 75 % RH; conductor centered in jaw
opening; no DC component; no adjacent conductor
40 A Range 400 A Range
Measurement Range: 0.5 A to 40 A 5 A to 400 A
Output: 10 mV/A 1 mV/A
Accuracy:
45 Hz to 3 kHz
2 % + 0.015 A 2 % + 0.04 A
Phase Shift:
(45 Hz to 400 Hz)
0.5 A to 1 A
1 A to 5 A
5 A to 10 A
10 A to 20 A
20 A to 40 A
40 A to 400 A
Unspecified
NA
NA
NA
Unspecified
1.5°
Crest Factor: 3 3 to 300 A
2.5 to 400 A
Typical Bandwidth: 5 Hz to 10 kHz
Working Voltage: 1000 V ac rms, in compliance with EN61010

Содержание

Скачать