CMI C-TP 250 — инструкция по эксплуатации и обслуживанию насосного оборудования [21/68]

Превью страниц Страница 21 / 68
CMI C-TP 250 [21/68] Storing
21
Operation
After the appliance has been connected to the mains
power supply, it is switched on and off automatically
by the float switch:
The pump begins to deliver when the float switch
is lifted up by the liquid(1).
The pump switches off when the float switch has
sunk to the bottom(2).
The cable for the float switch can be adjusted in the
cable holder(3). The distance between cut-in and
cut-off point is adjusted in this way:
Short cable: Cut-in and cut-off points are very
close together.
Long cable: Cut-in and cut-off points are very far
apart.
Cleaning and maintenance
Cleaning and maintenance overview
Before every use
After every use
Cleaning the appliance externally
Rinse with clean water. Remove stubborn contami-
nation with a brush and detergent.
Submerge the pump in a container with clean water
and switch on for a short time to rinse the inside of
the pump.
Cleaning the suction area
Clean all accessible insides of the casing.
Remove fibres which have wound around the
rotor shaft by opening the pressure connection.
Remove stubborn contamination with a brush
and detergent.
Storing
If there is a risk of frost, dismantle the appliance and
accessories, clean them and store in a place pro-
tected from frost.
Malfunctions and troubleshooting
In the event of a malfunction…
Malfunctions are often caused by minor faults. You
can easily remedy most of these yourself. Please
consult the following table before contacting the
vendor. You will save yourself a lot of trouble and
possibly money too.
Note: For operation with rope: Do not oper-
ate the pump without pressure hose. Avoid
the pump twisting around its longitudinal
axis.
NOTICE! Risk of damage to the appli-
ance! The float switch must be able to
move so that the submersible pump cannot
run dry.
What? How?
Check casing and cables
for damage.
Visual inspection.
Check float switch for
damage.
Lift and shake the switch
to check the free move-
ment of the contained
metal balls.
1
2
3
What? How?
Clean the appliance.
Note: Before using the pump again, first
“soak” it so that any possible dirt residues
do not block the appliance.
NOTICE! Risk of damage to the appli-
ance! Frost destroys the appliance and
accessories, as these always contain
water!
DANGER! Danger of physical injury and
death! Improperly conducted repairs may
prevent your appliance from working safely.
Such repairs will endanger you and your
surroundings.
Fault/malfunction Cause Remedy
Pump does not run. No mains voltage? Check cables, plug, socket and fuse.
Float switch does not operate? Ensure there is sufficient liquid present.
Ensure that the float switch can move suffi-
ciently.
Float switch defective? Contact your local vendor.
Motor overheats due to:
liquid temperature too high?
blocking by foreign bodies?
Eliminate the cause of the overheating (max.
temperature of liquid Technical data–
p.22).
GB