Invt CHV190-5R5G-4 Инструкция по эксплуатации онлайн [200/242] 471528

Invt CHV190-015G-4 Инструкция по эксплуатации онлайн [200/242] 471531
CHV190 series special inverter for crane
- 199 -
Function
Code
Name Description
Setting
Range
Factory
Setting
Modify
P2.11
Current without
load
0.01~655.35A 0.01~655.35
Depend
on model
P2.12
Magnetic pole
initial position
0.00~360.00 0.00~360.00
0.00
P2.13
Magnetic pole
position ampli
tude
gain
0.50~1.50 0.50~1.50
1
P2.14
C-
phase magnetic
pole position bias
0~9999 0~9999 433
P2.15
D-
phase magnetic
pole position bias
0~9999 0~9999 433
P2.16
Motor weak
magnetic
coefficient
0.1~2.0 0.1~2.0 1.0
P2.17
Motor minimum
weak magnetic
limitation
10.0~80.0% 10.0~80.0
50.0
P2.18
Weak magnetic
proportion
0~65535 0~65535 0
P2.19
Low-frequency
oscillation
suppression
tolerance
0~10 0~10 2
P2.20
High-frequency
oscillation
suppression
tolerance
0~10 0~10 0
P2.21
Motor output
maximum voltage
P2.04~550 P2.04~550
380
P2.22 Reserved 0~65535 0~65535 0
P3 Group: Vector control
P3.00
ASR low-speed
proportional gain
0~100 0~100 20

Содержание