CHV190 series special inverter for crane
- 200 -
Function
Code
Name Description
Setting
Range
Factory
Setting
Modify
P3.01
ASR low-speed
integral time
0.01~10.00s 0.01~10.00
0.50s
P3.02
Speed detection
low-speed filter
time
0.000~1.000s 0.000~1.000
0.000s
P3.03
Low switching
frequency
0.00Hz~P3.07 0.00~P3.07
5.00Hz
P3.04
ASR high-speed
proportional gain
0~100 0~100 25
P3.05
ASR low-speed
integral time
0.01~10.00s 0.01~10.00
1.00
P3.06
Speed detection
high-speed filter
time
0.000~1.000s 0.000~1.000
0.000s
P3.07
High switching
frequency
P3.03~P0.03 P3.03~P0.03
10.00Hz
P3.08
ACR proportional
gain P
0~65535 0~65535 500
P3.09
ACR integral
gain I
0~65535 0~65535 500
P3.10
Driver side slip
compensation
coefficients
50%~200% 50~200 100%
P3.11
Braking side slip
compensation
coefficients
50%~200% 50~200 100%
P3.12
Torque setting
source
0: Disabled
1: Keypad
2: AI1
3: AI2
4: 485 communication
5: Profibus
communication
0~7 0