Yaskawa CIMR-UU4A0034A [368/644] Auto tuning fault detection

Yaskawa CIMR-UU4A0040A [368/644] Auto tuning fault detection
Digital Operator Display Error Name
Er-21 Z Pulse Correction Error
Cause Possible Solutions
Motor was coasting when Auto-Tuning
was performed.
Make sure the motor has stopped completely. Restart Auto-Tuning.
Either the motor or the PG encoder on the
motor are not properly wired.
Check the wiring for the motor and the PG encoder. Restart Auto-Tuning.
The direction for the PG encoder is set
incorrectly, or the number of pulses set for
the PG encoder is wrong.
Check the direction and number of pulses set for the PG encoder. Restart Auto-Tuning.
PG encoder is damaged. Check the signal output from the PG encoder attached to the motor. Replace the PG if damaged.
Digital Operator Display Error Name
Er-25 High Frequency Injection Parameter Tuning Error
Cause Possible Solutions
Motor data was incorrect.
Perform Stationary Auto-Tuning and then perform High Frequency Injection Parameter Tuning again. If the
problem continues, high frequency injection control might not be possible with that motor.
Note: Auto-Tuning is not applicable for SPM motors.
6.7 Auto-Tuning Fault Detection
368
YASKAWA ELECTRIC SIEP C710636 04C U1000 Industrial MATRIX Drive Technical Manual

Содержание

Похожие устройства

Скачать