Yaskawa CIMR-UU4A0034A [510/644] B 1 n special adjustments

Yaskawa CIMR-UU4A0034A [510/644] B 1 n special adjustments
No.
(Addr.
Hex)
Name LCD Display Description Values Page
n8-51
(053E)
Acceleration/
Deceleration Pull-In
Current (for PM
Motors)
PM Pull-in I@Acc
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV/PM
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV/PM
Sets the d-Axis current reference during acceleration/
deceleration as a percentage of the motor rated current. Set to a
high value when more starting torque is needed.
Default: 50%
Min.: 0
Max.: 200
309
n8-54
(056D)
Voltage Error
Compensation Time
Constant
PM V Error CompT
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV/PM
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV/PM
Adjusts the value when hunting occurs at low speed. If hunting
occurs with sudden load changes, increase n8-54 in increments
of 0.1. Reduce this setting if oscillation occurs at start.
Default: 1.00 s
Min.: 0.00
Max.: 10.00
309
n8-55
(056E)
Load Inertia
PMLoad wk2 Ratio
0: Less than 1:10
1: 1:10 to 1:30
2: 1:30 to 1:50
3: More than 1:50
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV/PM
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV/PM
Sets the ratio between motor and machine inertia.
0: Below 1:10
1: Between 1:10 and 1:30
2: Between 1:30 and 1:50
3: Beyond 1:50
Default: 0
Min.: 0
Max.: 3
310
n8-57
(0574)
High Frequency
Injection
PM Harm Inj Sel
0: Disabled
1: Enabled
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
AOLV/PM
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
AOLV/PM
0: Disabled. Disable when using an SPM motor.
1: Enabled. Use this setting to enhance the speed control range
when using an IPM motor.
Default: 0
Range: 0, 1
310
n8-62
(057D)
Output Voltage Limit
(for PM Motors)
PM Vout Limit
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV/PM AOLV/PM CLV/PMOLV/PM AOLV/PM CLV/PM
Prevents output voltage saturation. Should be set just below the
voltage provided by the input power supply.
Default: 200.0
V
<3>
Min.: 0.0
Max.: 250.0
<3>
310
n8-69
(065D)
Speed Estimation Gain SpdSrch Gain
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
AOLV/PM
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
AOLV/PM
Sets the proportional gain for PLL control of an extended
observer.
There is normally no need to change this parameter from the
default value.
Default: 1.00
Min.: 0.00
Max.: 20.00
310
n8-72
(0655)
Speed Estimation
Method Selection
Spd Est method
0: Conventional
1: A1000 method
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
AOLV/PM
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
AOLV/PM
Sets the method to be used for estimating the speed.
0: Conventional method
1: 1000-series method
There is normally no need to change this parameter from the
default value.
Default: 1
Range: 0, 1
311
n8-84
(02D3)
Initial Polarity
Estimation Timeout
Current
Polarity Det Curr
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLV
OLV/PM AOLV/PM CLV/PMOLV/PM AOLV/PM CLV/PM
V/fOLV/PM
Sets the current to determine polarity for the initial polarity
calculation as a percentage of the motor rated current.
100% = Motor rated current
Note: If an “Si” value is listed on a Yaskawa motor
nameplate, set n8-84 to “Si” value x 2.
Default: 100%
Min.: 0
Max.: 150
311
<1> Default setting is determined by parameter n8-72, Speed Estimation Method Selection.
When n8-72 = 0, default is 50.0
When n8-72 = 1, default is 150.0.
<2> Default setting is determined by parameter E5-01, Motor Code Selection.
<3> Values shown are specific to 200 V class drives. Double the value for 400 V class drives.
B.11 n: Special Adjustments
510
YASKAWA ELECTRIC SIEP C710636 04C U1000 Industrial MATRIX Drive Technical Manual