Yaskawa CIMR-UU4A0034A [501/644] L4 speed detection

Yaskawa CIMR-UU4A0040A [501/644] L4 speed detection
No.
(Addr.
Hex)
Name LCD Display Description Values Page
L3-27
(0456)
Stall Prevention
Detection Time
Stl Prev DetTime
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f
OLV/PM
V/f w PGV/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f
OLV/PM
V/f w PG
Sets the time the current must exceed the Stall Prevention level
to activate Stall Prevention.
Default: 50 ms
Min.: 0
Max.: 5000
289
L3-36
(11D5)
Vibration Suppression
Gain during
Acceleration (with
Current Limit)
ILim Acc Gain
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f V/f w PG OLV
Increase the setting value if oscillation occurs in the output
current during acceleration.
Default:
<3>
Min.: 0.0
Max.: 100.0
289
L3-39
(11D5)
Current-limited Integral
Time Constant during
Acceleration
ILim Acc I Time
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f V/f w PG OLV
Sets the time constant for acceleration rate adjustment for current-
limited acceleration.
Default: 100.0
ms
Min.: 1.0
Max.: 1000.0
289
L3-40
(11D6)
Current-limited
Maximum S-curve
Selection during
Acceleration
ILimAcc S-Curve
0: Disable
1: Enable
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f V/f w PG OLV
0: Disable
1: Enable
Default: 0
Range: 0, 1
289
L3-41
(11D7)
Vibration Suppression
Gain during
Deceleration (with
Current Limit)
ILim Dec Gain
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f V/f w PG OLV
Increase the setting value if oscillation occurs in the output
current during deceleration.
Default:
<3>
Min.: 1.0
Max.: 100.0
289
L3-44
(11D8)
Current-limited Integral
Time Constant during
Deceleration
ILim Dec I Time
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f V/f w PG OLV
Sets the time constant for deceleration rate adjustment for current-
limited deceleration.
Default: 100.0
ms
Min.: 1.0
Max.: 1000.0
289
L3-45
(11D9)
Current-limited
Maximum S-curve
Selection during
Deceleration
ILimDec S-Curve
0: Disable
1: Enable
V/f
OLV/PM
V/f w PG
AOLV/PM
OLV
CLV/PM
CLVV/f V/f w PG OLV
0: Disable
1: Enable
Available when L3-04 = 6.
Default: 0
Range: 0, 1
289
<1> The default setting and upper limit are determined by C6-01, Drive Duty Selection, and L8-38, Frequency Reduction Selection.
<2> The setting range is 0 and 1 in OLV/PM, AOLV/PM, and CLV/PM control modes.
<3> Default setting is determined by parameter A1-02, Control Method Selection.
<4>
Default setting is determined by parameter A1-02, Control Method Selection.
When A1-02 = 6 (AOLV/PM), default is 0.2
When A1-02 = 7 (CLV/PM), default is 0.02.
u
L4: Speed Detection
No.
(Addr.
Hex)
Name LCD Display Description Values Page
L4-01
(0499)
Speed Agree Detection
Level
Spd Agree Level
All Modes
L4-01 sets the frequency detection level for digital output
functions
H2-oo = 2, 3, 4, 5.
Default: 0.0 Hz
Min.: 0.0
Max.: 400.0
289
L4-02
(049A)
Speed Agree Detection
Width
Spd Agree Width
All Modes
L4-02 sets the hysteresis or allowable margin for speed detection.
Default:
<1>
Min.: 0.0
Max.: 20.0
289
L4-03
(049B)
Speed Agree Detection
Level (+/-)
Spd Agree Lvl+-
All Modes
L4-03 sets the frequency detection level for digital output
functions
H2-oo = 13, 14, 15, 16.
Default: 0.0 Hz
Min.: -400.0
Max.: 400.0
290
L4-04
(49C)
Speed Agree Detection
Width (+/-)
Spd Agree Wdth+-
All Modes
L4-04 sets the hysteresis or allowable margin for speed detection.
Default:
<1>
Min.: 0.0
Max.: 20.0
290
B.10 L: Protection Function
YASKAWA ELECTRIC SIEP C710636 04C U1000 Industrial MATRIX Drive Technical Manual
501
B
Parameter List

Содержание

Похожие устройства

Скачать