Icom IC-751 [23/37] 4 scanning operation
Содержание
- Ic 75h 1
- Ic 75h 2
- General 4
- Receiver 4
- Section 1 specifications 4
- Transmitter 4
- All band all mode all solid state 5
- Dual vfo 5
- General coverage receiver capability 5
- Memories 5
- Other features 5
- Outstanding receiver performance 5
- Section 2 features 5
- Transmitter 5
- 1 unpacking 6
- 2 recommendations for 6
- 3 power supply 6
- Be sure to read the following instructions carefully before operation 6
- Installation 6
- Section 3 installation 6
- 10 headphones 7
- 4 antenna 7
- 5 ground 7
- 6 microphone 7
- 8 cw key 7
- 8 rtty 7
- 9 external speaker 7
- 1 front panel 8
- 11 cooling fan 8
- By the monitor curcuit the fan will operate during both 8
- Cause of the overheating before starting to transmit again 8
- Cooling but with 200 watts input the final stage produces 8
- If the temperature rises to a danger limit 90 c the fan 8
- Mit modes 8
- Of the final stage the fan operates as follows 8
- Overheating i e antenna mismatch etc and correct the 8
- Perature monitoring circuit which monitors the temperature 8
- Plug inserted completely only the headphone works 8
- Power is reduced to 50 watts investigate the cause of 8
- Prolonged transmissions the fan is connected to a tem 8
- Quite a bit of heat and its temperature may rise during 8
- Section 4 operating controls 8
- The fan does not operate both in the receive and thans 8
- The headphone will lose the sound on one side with the 8
- The rear of the pa unit is designed to provide for adequate 8
- Transmit and receive to provide additional cooling 8
- Using a tape recorder connected to the headphone jack 8
- When the temperature rises to a point 50 c detected 8
- Will run much more rapidly at this time the output 8
- With a stereo headphone set inserted this way however 8
- 2 top cover 13
- 3 rear panel connections 13
- And attenuator are removed from the circuit and incoming 13
- Anti vox circuit with this control along with the vox 13
- Anti vox control 13
- Attenuation 13
- Calibrates the marker frequency with a standard frequency 13
- Controls the audio level of the monitoring ssb or cw side 13
- For normal operation leave this switch in the off 13
- Gain control so that the vox circuit only operates by the 13
- In vox operation the vox circuit may be operated by 13
- Marker calibrator 13
- Marker switch 13
- Monitor level control 13
- Operator s voice not by sound from the speaker 13
- Position 13
- Preamp att attenuator switch 13
- Put in the rf circuit and provides higher sensitivity 13
- Quency is available on every 10khz 13
- Signals will be fed to the receiver directly 13
- Sound from the speaker causing a switch to transmit this 13
- Such as the wwv 13
- Switches rf preamplifier and attenuator in the rf circuit 13
- The attenuator into the circuit this gives about 20db 13
- The switch in the pre position and the preamplifier is 13
- This removes the preamplifier from the circuit and inserts 13
- Tone when the monitor switch on the front panel is 13
- Trouble can be prevented by adjusting the input level of the 13
- Turned on adjust the control for comfortable monitoring 13
- Turns the marker circuit on or off the marker fre 13
- Very strong signal set this switch in the att position 13
- When nearby signals interfere with reception or receiving a 13
- When the switch is in the off position both preamplifier 13
- When using a small antenna or receiving a weak signal set 13
- 1 how to tune 15
- Section 5 operating instructions 15
- N n n 1 19
- 2 memory channel operation 20
- 3 tuning by up down buttons on 22
- The microphone 22
- 4 scanning operation 23
- 5 ssb operation 24
- 6 cw operation 26
- 7 rtty operation 27
- 8 am operation 28
- 9 fm operation 28
- 10 general coverage receiver 29
- 11 other operations 29
- 1 installation of optional filter 31
- Section 6 option installation 31
- 2 built in power supply unit 32
- Ic ps35 32
- Ic ом 37
Похожие устройства
- Ardo DWB09L6X Инструкция по эксплуатации
- Icom IC-756 Инструкция по эксплуатации
- Ardo FLOI86E Инструкция по эксплуатации
- Samsung GT-C3322 Metallic Black chat on Инструкция по эксплуатации
- Icom IC-756PRO Инструкция по эксплуатации
- Ardo FLOI147L Инструкция по эксплуатации
- Samsung GT-S5222 Black Инструкция по эксплуатации
- Icom IC-756PROII Инструкция по эксплуатации
- Ardo FLOI126L Инструкция по эксплуатации
- Nokia Asha 305 Dark Grey Инструкция по эксплуатации
- Icom IC-756PROIII Инструкция по эксплуатации
- Ardo FLOI106S Инструкция по эксплуатации
- Texet TX-D6205A Black Инструкция по эксплуатации
- Icom IC-775DSP Инструкция по эксплуатации
- Ardo DWC06S5B Инструкция по эксплуатации
- Icom IC-207H Инструкция по эксплуатации
- Ardo DWC06E3W Инструкция по эксплуатации
- Texet TX-D6205A Black/Red Инструкция по эксплуатации
- Icom IC-2100H Инструкция по эксплуатации
- Ardo FLSN 103 EW Инструкция по эксплуатации
When the set is scanning in the normal memory scan mode push the MODE SELECTIVE switch in at the moment that your desired mode is displayed on the display 5 4 3 PROGRAMMED SCAN This is to scan between two desired frequencies which are memorized in the memory channels 1 and 2 CAUTION The programmed scan does not start when the contents of memory channels 1 and 2 and frequency display differ from which are described below This function is effective in the VFO mode and when the DFS switch is pushed in to change the operating frequency in the MEMORY CHANNEL mode 1 The same operation mode HAM BAND or GENERAL COVERAGE mode should be stored into memory channels 1 and 2 To start the scan the set should be in the same operation mode as the memory channels 2 Stored frequencies in memory channels 1 and 2 should be in the same band if the HAM BAND mode is stored in both memory channels 1 and 2 To start the scan the set should be in the HAM BAND mode and in the same band as the memory channels 5 3 2 MEMORY CHANNEL SELECTING In the MEMORY CHANNEL mode or when the DFS switch is pushed in to change the displayed memory chan nel number in the VFO mode by depressing the UP or DN down button on the microphone continuously the operating MEMORY CHANNEL or displayed channel number is changed up or down respectively every two seconds 5 4 SCANNING OPERATION 1 Memorize the frequencies of the high and low edges of the desired scanning range into the memory channels 1 and 2 Regardless of which channel the higher frequency is memorized in the scan starts from the high edge of the range For example 14 200MHz is in the memory channel 1 and 14 300MHz in the channel 2 The IC 751 provides various scanning operations Please read the following instructions carefully to fully enjoy the IC 751 s many capabilities 5 4 1 MEMORY SCAN This is used to scan all programmed memory channels continuously 2 Place the unit in the VFO MODE and select operation mode the same as the channels 1 and 2 and a VFO you desire Pushing the SCAN START STOP button starts the scan from the high edge 14 300MHz to the low edge 14 200MHz The scanning frequency increments depend on the TUNING RATE SELECT switch setting 1 Program your desired frequencies into memory channels 2 Select a memory channel programmed with a frequency The scan cannot start from a blank channel 3 Depress the SCAN START STOP button and the fre quency starts scanning the programmed frequencies in the memory channels from the highest channel to lowest At this time the scan skips blank channels if any 3 When the scanning frequency reaches the low edge 14 200MHz it automatically returns to the high edge 14 300MHz and continues scanning down to provide endless scanning operation 4 If the SQUELCH is engaged the scan stops when the squelch is opened and receives a signal This restarts after passing a specified time 4 While the SQUELCH is engaged the squelch opens when a signal is received and will stop the scanning automati cally on the frequency and the signal can be monitored After approximately 10 seconds the scan restarts from the frequency the scan stopped at continuing to the low edge If the RECEIVE indicator is lit because the SQUELCH is not engaged the scan does not stop at any signals To stop scanning without opening the squelch depress the SCAN START STOP button Depress it again to restart the scanning 5 4 2 MODE SELECTIVE SCAN In the memory scan mode by pushing the MODE SELEC TIVE SCAN switch in the scan scans only on channels having the desired operating mode 5 Depressing the SCAN START STOP button while the scan is operating or during the 10 seconds of monitoring clears the scanning operation and the VFO goes back to normal operation To be in this scan mode first select a channel that has your desired mode second push the MODE SELECTIVE switch in then the SCAN START STOP button 20