Haier AC242ACEAA [253/408] Installation

Haier AD362AMERA [253/408] Installation
30mA
Item
Model
Phase
1
Switch breaker
(A)
Circuit breaker
Overcurrent
protector
Power source
wire size
(minimum)
40 26 2.5mm
2
1
60 40 4.0mm
2
Switch
break
Earth leakage breaker
Leak
curren
40A 30mA
60A
AU182AEEAA
AU122AEERA
AU182AFERA
AU242AGERA
AU362AHERA
AU282AHERA
AU362AIERA
1 60 40 6.0mm
2
60A 30mA
AU28NAHEAA
AU36NAIEAA
AU36NAHERA
AU48NAIERA
3 30 20 2.5mm
2
30A 30mA
AU48NAIEAA
AU60NAIEAA
AU60NAIERA
3 30 20 4.0mm
2
30A 30mA
AU242AGEAA
1 40 26 4.0mm
2
40A 30mA
AU282AHEAA
AU362AIEAA
1 40 26 6.0mm
2
40A 30mA
(2) Wiring connection
For the detailed wiring connection with the indoor units, see the corresponding indoor
operation and instruction manual.
For: AU182AEEAA AU122AEERA
FIG.2
OUTDOOR UNIT
TERMINAL BLOCK
FIG.1
1 2 3
To Indoor Unit
Y/G
For: AU242AGEAA AU282AHEAA AU362AIEAA
AU182AFERA AU242AGERA AU282AHERA
AU362AHERA AU362AIERA
L N
POWER SUPPLY
380-400V, 3N~, 50Hz
N 1 2 3
Y/G
To Indoor Unit
R S T
FIG.3
For: AU28NAHEAA AU36NAIEAA AU48NAIEAA AU60NAIEAA
AU36NAHERA AU48NAIERA
AU60NAIERA
OUTDOOR UNIT
TERMINAL BLOCK
POWER SUPPLY
1PH, 220-230V~, 50Hz
1 2 3
Y/G
OUTDOOR UNIT
TERMINAL BLOCK
To Indoor Unit
WARNING!
INTERCONNECTING WIRES MUST BE WIRED ACCORDING TO FIG.1,FIG.2,
FIG.3 INCORRECT
WIRING MAY CAUSE EQUIPMENT DAMAGE.
(3) Wiring procedure
1) Remove set screws on the side before taking off the front panel toward the direction shown
in figure.
2) Connect wires to the terminal block correctly and fix the wires with a wire clamp equipped
3) Route the wires in a proper way and penetrate the wires through the opening for electric
nearby the terminal
block.
wiring on the side
panel.
Installation
-236-