Haier AC242ACEAA [346/408] Failure code

Haier AB282AEEAA [346/408] Failure code
1.2 For outdoor units
Code on wired
controller
Flash times of indoor
receiver board
Room temp. sensor abnormal 01 Power LED flashes 1 time
Indoor coil temp. sensor abnormal 02 Power LED flashes 2 times
Outdoor temp. sensor abnormal 4A Power LED flashes 3 times
Outdoor coil temp. sensor abnormal 49 Power LED flashes 4 times
48 Power LED flashes 5 times
High / Low pressure abnormal 53 Power LED flashes 6 times
Communication malfunction between indoor and wired
controller
07 Power LED flashes 8 times
Communication malfunction between indoor and outdoor
abnormal
06 Power LED flashes 9 times
Drainage system malfunction 08 Power LED flashes 10 times
Alarm of exterior annunciator 0B Power LED flashes 11 times
Coil gas pipe temp. Sensor abnormal 03 Power LED flashes 12 times
Temperature protection malfunction 0D Power LED flashes 13 times
Failure description
Over-current malfunction/Power failure
1.2.1 For fixed frequency outdoor unit( EAA)
*
Failure code
-329-