38
Smart Power
Item Model ADH125M1ERG/1UH125P1ERG
Function Cooling Heating
Capacity
kW
12.5 (3.5~15.0) 13.7(4~18.0)
Sensible heat ratio 0.74 /
Total power input
kW
3.67 (1.0~6.5) 3.91 (1.0~6.5)
Max. power input
W
6500 6500
AEER or ACOP
W/W
3.37 3.47
Dehumidifying capacity
10
-3
×m
3
/h
4.9
Power cable 6.0mm
2
Power source
N, V, Hz
1ph, 220~240, 50/60
Running/Max. Running current A/A
17.0 (8.7-30.0) /30A 17.5 (8.7-30.0) /30A
Start current
A
3
Circuit breaker
A
40
Indoor
unit
Unit model (color) ADH125M1ERG
Fan
Type×Number CENTRIFUGALX3
Speed (H-M-L)
r/min
1100/1000/950
Fan motor output power/input power
kW
0.32/0.4
Air-ow(H-M-L)
m
3
/h
2250/1960/1680
ESP
Pa
30-120
Heat
exchanger
Type/Diameter
mm
Inner grooved pipe/φ7.0
Total area
m
2
/
Dimension
External (L×W×H)
mm×mm×mm
1500/700/250
Package (L×W×H)
mm×mm×mm
1710/865/320
Drainage pipe (material, I.D./O.D.)
mm
PVC 26/32
Controller (O-Optional, S-Standard)
Wired
YR-E17 (S)/YR-E16A(O)
Infrared
YR-HBS01 (O)
Fresh air hole dimension
mm
125
Electricity heater
kW
/
Sound power noise level (H)
dB (A)
62
Sound pressure noise level (H-M-L)
dB (A)
39/36/33/31
Weight (Net / Shipping)
kg / kg
52/62
Piping
Refrigerant
Type / Charge
g
R410A/3700
Recharge quantity
g/m
45
Pipe
Liquid mm 9.52
Gas mm 15.88
Max.pipe lengh without
charge refrigerant
m 30
Between
I.D&O.D
MAX.Drop m 30
MAX.Piping length m 75
Connecting method Flared
Norminal condition:
Indoor temperature (cooling) : 27DB (°C)/19WB (°C) , Indoor temperature (heating) : 20DB (°C)
Outdoor temperature (cooling) : 35DB (°C)/24WB (°C) , Outdoor temperature (heating) : 7DB (°C)/6WB (°C)
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity
meter. It is a sound pressure noise level.