8.3. OXYGEN ENRICH OPERATION
8.3.1. Purpose
Increase usage range by enable oxygen enrichment only operation.
8.3.2. Oxygen Enrichment Control -1
A. Indoor fan control
1. Air flow volume manual
Air flow volume as set by remote control. Speed same as for Cool mode.
2. Air flow volum auto
Repetition of 8 pattern (a ~ h) as shown below.
Each pattern, 10s
XE9CK XE12CK
Quiet
Program Air
No. B 820 870
No. A 790 840
No. C 760 810
W C 30 30
However, if combined operation with other mode, priority is given to fan control of other mode.
Priority: Cool - Dry - Fan - Heat > Ionizer > Oxygen
B. Indoor air direction control
1. Air flow direction manual, auto same as cooling operation.
However when combined operation with other mode, priority is given to air flow direction control of other mode.
Priority Heat - Cool - Dry - Fan > Ionizer > Oxygen
C. Start & Cancel condition of Oxygen enrich operation
1. By remote control ON/OFF button.
a. During Ionizer and Air Conditioner is OFF, if Oxygen button is pressed
Oxygen only operation.
b. During Ionizer only operation, if Oxygen button is pressed
Ionizer + Oxygen enrich operation.
c. During Oxygen only operation, If Oxygen button is pressed
Oxygen operation stop.
d. During Oxygen only operation, if ON/OFF button is pressed
Mode (as remote control setting) operation + Oxygen operation.
e. During Cool, Fan, Heat, Dry, Ionizer operation, if Oxygen button is pressed
Cool, Fan, Heat, Dry, Ionizer + Oxygen operation, if Oxygen button is pressed.
f. During Cool, Fan, Heat, Dry, Ionizer + Oxygen operation, if Oxygen button is pressed.
Cool, Fan, Heat, Dry, Ionizer operation.
g. During Cool, Fan, Heat, Dry, Ionizer + Oxygen operation, if ON/OFF button is pressed
All operation stop.