MOTU Micro Lite Руководство по эксплуатации онлайн [47/166] 776062

MOTU Micro Lite Руководство по эксплуатации онлайн [47/166] 776062
CLOCKWORKS FOR MAC OS X
47
MIDI Machine ID
The MIDI Machine ID option lets you change the MMC
(MIDI Machine Control) device ID of your MOTU
interface. The factory default ID of your MOTU interface
is 19. The only situation in which you really need to change
it is if you are using MIDI Machine Control with two or
more MOTU interfaces. Otherwise, just leave it set to 19,
and make sure that your MMC transport master controller
device or computer software knows that your MOTU
interfaces ID is 19.
If you change your MOTU interface device ID for some
reason, make sure that it does not match the ID of another
device connected to it.
Freewheel _ frames
This option lets you set the number of frames your MOTU
interface will freewheel over when it encounters a time
code drop-out. For a complete explanation of
freewheeling, see “Freewheeling to avoid time code
dropouts on page 115.
Infinite freewheel
When you choose this option, your MOTU interface
begins generating time code on its own indefinitely as
soon as it stops receiving incoming time code. And it will
continue to do so until you stop it with the STRIPE button
on the front panel. You can also stop it by changing the
master sync mode or by enabling the Freewheel option in
ClockWorks.