Clavia Nord Modular & Micro Modular V3 [139/232] Ad env

Clavia Nord Modular & Micro Modular V3 [139/232] Ad env
NORD MODULAR V3.0 7. Module reference: Envelope group
Page 131
O
OO
O
U
UU
UT
TT
TP
PP
PU
UU
UT
TT
T
The red output from the envelope controlled amplifter.
Signal:
Bipolar
.
AD-E
AD-EAD-E
AD-E
N
NN
NV
VV
V
This is a smaller envelope with two stages, attack and decay. If the envelope finishes the attack stage while
still receiving a high Gate signal, the envelope proceeds with the decay stage. If the logic Gate signal drops
to zero during the attack stage, the envelope starts the decay stage with the set decay time.
G
GG
G
A
AA
AT
TT
TE
EE
E
/T
/T/T
/T
R
RR
RI
II
IG
GG
G
S
SS
SE
EE
EL
LL
LE
EE
EC
CC
CT
TT
TO
OO
OR
RR
R
This determines whether the envelope should behave like a gated envelope or like an unconditional en-
velope. The gated (Gate mode) envelope needs a high logic signal for at least a short period of the attack
stage. The unconditional (Trig mode) envelope only needs a short high logic signal to start. When the
envelope has started after a Trig signal, it will proceed to the very end of the cycle even if the Trig signal
drops to zero. Please note the arrow that appears next to the yellow input when Trig mode is selected.
G
GG
G
A
AA
AT
TT
TE
EE
E
/T
/T/T
/T
R
RR
RI
II
IG
GG
G
I
I I
I
N
NN
NP
PP
PU
UU
UT
TT
T
A high logic signal at this yellow input will start the envelope. The LED lights up while the envelope is
receiving a high logic signal.
A
AA
A
M
MM
MP
PP
P
I
II
IN
NN
NP
PP
PU
UU
UT
TT
T
A blue control signal input used for controlling the overall amplitude of the envelope.
A
AA
A
T
TT
TT
TT
TA
AA
AC
CC
CK
KK
K
Sets the attack time. When the envelope receives a high logic signal at the Gate/Trig input, the output
control signal from the envelope rises up to the maximum output, +64 units. The time to get from 0 to
+64 units is the attack time. The attack is linear. If the logic Gate signal drops to zero before the envelope
has completed the attack stage, it will immediately proceed with the decay stage. If the logic input is set
to Trig, the entire attack phase will be completed. The attack time is displayed in milliseconds or seconds
in the display box. Range: 0.5 ms to 45 s.
Note: A very short attack time can produce a click in the be-
ginning of the sound. This is only normal according to physics theory. To eliminate any click, just in-
crease the attack time slightly.
D
DD
D
C
CC
CY
YY
Y
Sets the decay time. After the envelope has completed the attack part, it will drop down to 0 units with
the decay time. The decay is exponential. If the logic Gate/Trig signal drops to zero before the envelope
has completed the decay stage, it will still continue through the whole decay stage. The decay time is dis-
played in milliseconds or seconds in the display box. Range: 0.5 ms to 45 s.
G
GG
GR
RR
RA
AA
AP
PP
PH
HH
H
The info graph shows an approximation of the envelope gain curve.
I
II
IN
NN
NP
PP
PU
UU
UT
TT
T
The red audio signal input. Here you patch a signal to the envelope controlled amplifter.