Bosch GLL 3-50 +вкладка L-BOXX [14/254] Technical data

Bosch GLL 3-50 +вкладка L-BOXX [14/254] Technical data
14 | English
(1)
Laser beam outlet aperture
(2)
Receiver mode indicator
(3)
Receiver mode button
(4)
Button for laser operating mode
(5)
Battery warning
(6)
1/4" tripod mount
(7)
Battery compartment cover
(8)
Battery compartment cover locking mechanism
(9)
5/8" tripod mount
(10)
Laser warning label
(11)
Serial number
(12)
On/off switch
(13)
Guide groove
(14)
Locking screw for telescopic leg
(15)
Fine adjustment screw of the rotating platform
(16)
Rotating platform
(17)
Guide rail
(18)
Magnet
(19)
Laser target plate
(20)
Laser goggles
a)
(21)
Tripod (BT150)
a)
(22)
Telescopic shaft (BT350)
a)
(23)
Laser receiver
a)
(24)
Laser receiver holder
a)
(25)
Universal holder (BM1)
a)
(26)
Case
a)
a)
Accessories shown or described are not included with the
product as standard. You can find the complete selection of
accessories in our accessories range.
Technical Data
Cross line laser GLL 3-50
Article number
3 601 K63 8..
Working range
A)
Standard laser lines 10m
Laser lines with laser re-
ceiver
5–50m
Plumb point 5m
Levelling accuracy
B)C)
Laser lines ±0.3mm/m
Plumb point ±0.6mm/m
Typical self-levelling range ±4°
Typical levelling time <4s
Operating temperature –10°Cto+40°C
Storage temperature –20 °Cto+70 °C
Max. altitude 2000m
Relative air humidity max. 90%
Cross line laser GLL 3-50
Pollution degree according to
IEC61010-1
2
D)
Laser class 2
Laser type <1mW, 630−650nm
C
6
1
Divergence of laser line 0.5mrad (full angle)
Shortest pulse duration 1/1600s
Pulse frequency (operating with
receiver mode)
800Hz
Recommended laser receiver LR 2
Tripod mount 1/4", 5/8"
Batteries 4×1.5V LR6(AA)
Min. operating time
B)
6h
Weight according to
EPTA‑Procedure01:2014
0.94kg
Dimensions (length×width×height)
without rotating platform 146×83×117mm
with rotating platform Dia.:201× 197mm
Protection rating IP54 (dust and splash-
proof)
A) The working range may be reduced by unfavourable environ-
mental conditions (e.g. direct sunlight).
B)
At 20–25°C
C) The values stated presuppose normal to favourable environ-
mental conditions (e.g. no vibration, no fog, no smoke, no direct
sunlight). Extreme fluctuations in temperature can cause devi-
ations in accuracy.
D) Only non-conductive deposits occur, whereby occasional tem-
porary conductivity caused by condensation is expected.
The serial number (11) on the type plate is used to clearly identify
your measuring tool.
Assembly
Inserting/Changing the batteries
It is recommended that you use alkaline manganese batter-
ies to operate the measuring tool.
To open the battery compartment cover(7), pull the locking
mechanism(8) and lift the battery compartment cover. In-
sert the batteries.
When doing so, ensure that the polarity is correct and cor-
responds to the diagram on the battery compartment cover.
If the battery warning (5) flashes red, the batteries must be
replaced.
Always replace all the batteries at the same time. Only use
batteries from the same manufacturer and which have the
same capacity.
u Take the batteries out of the measuring tool when you
are not using it for a prolonged period of time. The bat-
teries can corrode and self-discharge during prolonged
storage in the measuring tool.