COIL CURRENT (CC) [1- 2] Sets the level of current supplied to the coil. At
A setting of 2 (TURBO) maximum current is applied to the coil. Maximum depth
ability is achieved however operating time is decreased due to increased battery
usage. At the minimum setting of 1 maximum battery time is achieved at the cost of
reduced depth.
The remark. If operating near sources of electrical interference or other detectors
it is advised to set CC to 2 (turbo) and reduce sensitivity in order to reduce these
affects. On the other hand it may be necessary to reduce CC to 1 in order to
minimize the interference on other devices close by.
RECOVERY SPEED (RS) [1- 9] defines speed of the automatic tuning under
ground conditions in the dynamic mode (This setting has no affect in the pinpoint
or static mode). Reducing the speed of auto will increase the depth of search.
However in areas of considerable ground mineralization, target ID reliability can
worsen. There can be false responses from the ground, and also separation of the
closely spaced targets worsens. Lower settings of the recovery speed are
recommended for areas with deep targets, areas with low mineralization and areas
with little metal trash. It is also important to use a slower steady sweep speed
avoiding erratic movements, jerking etc. as well as keeping the coil parallel to the
ground. Increase in recovery speed settings is recommended for areas with many
closely spaced targets where target separation is most important. It is not
recommended to set the RS below 5.
AUDIO THRESHOLD (AT) [0- 20] defines the minimum signal level required to
generate an audio response on a detected object. Reducing the Audio Threshold
setting increases the sensitivity to small and deep targets but also increases the risk
of false audio responses. The device will react to the smallest particles of metal as
well as possible ground mineral concentrations. To achieve maximum depth of
search set the Audio Threshold as low as possible without creating excessive false
responses from the ground. Increasing the Audio Threshold will improve the
comfort of search by reducing false ground responses but at the expense of
reducing depth sensitivity. Unless there is a special reason to do so, do not set
the level too high as a loss in response sensitivity to large nonferrous items can
occur.
GAIN (GN)[0- 20] Defines overall sensitivity of the metal detector. The higher the
Gain the deeper the ability of the detector as well as increased response from smaller
targets. To achieve maximum depth and target response set the gain as high as
possible while still maintaining a stable detector. In areas of excessive ground
minerals or areas with a lot of metal trash it will be necessary to reduce gain levels
to a lower level. It is not recommended to set the gain to the maximum level
especially in areas with mineralization as performance will decrease at these
excessive settings. In most cases a maximum setting of 16 is recommended to avoid
false responses.
IDENTIFICATION THRESHOLD (IT) [0- 20] Defines the minimum signal level
required to generate a target ID audio response as well as to display a VDI value. If
a target is detected but does not meet the minimum signal level an audio
response from the threshold will be heard but no VDI number will be displayed.
Lower values will increase the depth response for target ID but reliability as well
1
7
Содержание
- Berkut 5 1
- Operating instructions 1
- General information 4
- Included in the box 4
- Technical characteristics 5
- Introduction 6
- Assembling your berkut 5 7
- The front panel 8
- The back panel 9
- The display 10
- Starting up the device 11
- S k m an turbo 003 12
- The coil is not compensated repeat compensation 12
- The start menu 12
- D9x12 14 14
- Ground balancing 14
- Select 14
- Select profile of coil 14
- A fn 180 15
- Ad fn 180 15
- М 002 бг 003 15
- М 102 бг 005 15
- Adjusting the key parameters 16
- Gain 15 16
- Additional parameters 18
- Display search discriminate other coils 18
- Main menu 18
- The audio menu 19
- A low tone will be generated for ferrous targets while a 20
- A low tone will be generated for small ferrous objects whose border has been determined by setting border fe a medium tone will be generated for targets just above the border fe setting but below vdi 15 a high tone will be generated for targets within vdi 15 to 90 range 20
- Equalizer 20
- High tone will be generated for all non ferrous targets the border for these tones can be set under border fe option previously mentioned 20
- Under this setting the duration is the same as for non ferrous targets whereby the duration is based upon size shape and strength 21
- Accumulation off 22
- Backlight on 22
- Display backlight lev 5 22
- Display menu 22
- Screen scale 3 22
- Visual disc off 22
- Search menu 23
- The discrimination menu 25
- The other menu 26
- Coil d6x10 14 28
- D6x10 7 1 28
- Editor 28
- On on auto fr 06725 ort 095 ph 018 28
- The coil menu 28
- Dynamic and static operating modes 29
- Discrimination map 30
- Discrimination mode of search 30
- Дискр the menu дискр the menu 30
- Дискр the menu 31
- Mode of training of the discriminator 32
- Sector of the special signal 32
- A overload 33
- Overload mode 33
- S k m an turbo 33
- User programs 33
- Intended for searching smaller objects that are deeper 34
- Replacing the search coil 34
- Batteries 35
- Charge or 35
- Low batteries 35
- Replace the battery 35
- D6x10 14 2 36
- Fr 13890 36
- Ort 047 ph 244 36
- Program adjustment of coils 36
- Use of headphones 36
- Addition of a new coil to a new profile 37
- Adjusting the new coil to the current profile 37
- Some councils about operation 38
- Storingyour metal detector 38
- Металлодетектора 38
- About ground balancing 39
- Scanning techniques 39
- Councils about identification of types 40
- Of objects 40
- About the pinpoint mode 41
- About equalizer use 42
- Examples of some vdi 42
- Acceptance certificate 43
- Guarantee certificates 43
Похожие устройства
- Ака БЕРКУТ-5 7253_5_20 Руководство пользователя
- Ака Беркут-5 версия 5.99 rev.03 Руководство пользователя
- Ака Пилигрим 7247 4АА / 6АА Руководство пользователя
- Ака СИГНУМ MFT модель 7272М версия 1.00 Руководство пользователя
- Ака Signum 7272M MFT version 1.00 Руководство пользователя
- Ака СИГНУМ MFT/MFD модель 7272М версия 2.0х Руководство пользователя
- Ака Intronik STF Руководство пользователя ч2
- Ака Intronik STF Руководство пользователя
- Ака Intronik STF Краткая инструкция по эксплуатации
- Ака Разгрузка Руководство пользователя
- Ака Сорекс Pro 7281 Руководство пользователя
- Ака УНИСКАН модель 7215М Руководство пользователя
- ACV BOILER TKAN 300 По Монтажу, эксплуатации и обслуживанию котла
- Kuppersberg WM 490 W Инструкция по эксплуатации
- Kuppersberg WM 410 W Инструкция по эксплуатации
- Kuppersberg WID 56149 W Инструкция по эксплуатации
- Kuppersberg WDM 560 Инструкция по эксплуатации
- Kuppersberg WM 581 W Инструкция по эксплуатации
- Kuppersberg WM 520 W Инструкция по эксплуатации
- Kuppersberg WM 411 W Инструкция по эксплуатации