Moxa UC-8416-T-LX Инструкция по эксплуатации онлайн [19/90] 170872

Moxa UC-8410-LX Инструкция по эксплуатации онлайн [19/90] 170868
UC-8410/8416/8418/8430 Managing Embedded Linux
3-3
root@Moxa:/# upramdisk
root@Moxa:/# df -h
Filesystem Size Used Available Use% Mounted on
/dev/mtdblock2 14.0M 11.2M 2.8M 80% /
/dev/ram15 1.7M 18.0k 1.6M 1% /dev
/dev/ram0 499.0k 34.0k 440.0k 7% /var
/dev/mtdblock3 15.8M 2.6M 13.1M 17% /tmp
/dev/mtdblock3 15.8M 2.6M 13.1M 17% /home
/dev/mtdblock3 15.8M 2.6M 13.1M 17% /etc
/dev/ram1 38.7M 13.0k 36.7M 0% /mnt/ramdisk
root@Moxa:/# cd /mnt/ramdisk/
root@Moxa:/mnt/ramdisk#
The following instructions give the steps required to save the firmware file to the UC-8410/8416/8418/8430’s
RAM disk, and then upgrade the firmware.
1. Type the following commands to enable the RAM disk:
#upramdisk
#cd /mnt/ramdisk
2. Type the following commands to use the UC-8410/8416/8418/8430’s built-in FTP client to transfer the
firmware file (FWR_uc8400_Va.b.c_Build_YYMMDDHH.hfm ) from the PC to the
UC-8410/8416/8418/8430:
/mnt/ramdisk> ftp <destination PC’s IP>
Login Name: xxxx
Login Password: xxxx
ftp> bin
ftp> get FWR_uc8400_Va.b.c_Build_YYMMDDHH.hfm
192.168.3.127 – PuTTY
root@Moxa:/mnt/ramdisk# ftp 192.168.3.193
Connected to 192.168.3.193 (192.168.3.193).
220 TYPSoft FTP Server 1.10 ready…
Name (192.168.3.193:root): root
331 Password required for root.
Password:
230 User root logged in.
Remote system type is UNIX.
Using binary mode to transfer files.
ftp> cd newsw
250 CWD command successful. “/C:/ftproot/newsw/” is current directory.
ftp> bin
200 Type set to I.
ftp> ls
200 Port command successful.
150 Opening data connection for directory list.
drw-rw-rw- 1 ftp ftp 0 Nov 30 10:03 .
drw-rw-rw- 1 ftp ftp 0 Nov 30 10:03 .
-rw-rw-rw- 1 ftp ftp 12904012 Nov 29 10:24
FWR_uc8400_Va.b.c_Build_YYMMDDHH.hfm
226 Transfer complete.
ftp> get FWR_uc8400_Va.b.c_Build_YYMMDDHH.hfm
local: FWR_uc8400_Va.b.c_Build_YYMMDDHH.hfm remote:
FWR_uc8400_Va.b.c_Build_YYMMDDHH.hfm
200 Port command successful.

Содержание

Скачать