Autel Autolink AL519 [66/73] Ready test
65
6. Ready Test
This function can be used as a convenient readiness test tool by
automotive technicians to determine if the tested vehicle is
ready for an emission test. By visual and audible indication,
you will learn a vehicle’s monitors readiness.
6.1 General Information
Repairs to the emissions-control systems of a 1996 or newer vehicle
cause the vehicle‟s computer (ECU) memory to be cleared. The
vehicle must go through a drive cycle to allow the ECU to perform a
series of tests to ensure that the repair was successful, and before a
state mandated emissions test can be conducted. But how will you
know when it is ready?
With this scan tool, you don‟t have to drive around endlessly and
continuously coming back to the repair shop for retest if all required
tests by the ECU are completed. And you could also do a quick check
of the vehicle to determine if it is ready to receive an emission test
without the hassle of connecting your vehicle to the analyzer or
having to use a complicated scan tool.
In the following cases, this function is especially useful.
You bought a used car and the check engine light had been
cleared to mask potential problems.
You disconnected the battery for tune-ups and other engine
repairs, dead battery replacement, car radio installation and car
alarm installation.
You used a scan tool to clear the DTCs.
Your car has been sent to repair.
6.2 Ready test application
Содержание
- Table of contents 1
- Safety precautions and warnings 2
- Diagnostic trouble codes dtcs 3
- General information 3
- On board diagnostics obd ii 3
- Dtc example 4
- Location of the data link connector dlc 4
- P 0 2 0 2 4
- Obd ii readiness monitors 5
- Obd ii monitor readiness status 6
- Obd ii definitions 7
- Obd ii modes of operation 8
- Tool description 11
- Using the scan tool 11
- Accessories included 13
- Navigation characters 13
- Specifications 13
- Dtc lookup 14
- Keyboard 14
- System setup 16
- To enter the setup menu 16
- Configure monitors 17
- Language setup 17
- Spark ign required monitors 18
- Compression ign required monitors 19
- Unit of measure 19
- Key beep set 20
- Status beep set 21
- Tool self test 21
- Update mode 23
- Vehicle coverage 25
- Operating error 26
- Product troubleshooting 26
- Vehicle linking error 26
- Led lamps not working 27
- Scan tool doesn t power up 27
- Review data 28
- Obdii diagnostics 30
- Reading codes 32
- Erasing codes 34
- Live data 36
- Viewing data 36
- Figure 5 7 40
- Figure 5 8 40
- If you decide to deselect these items press ok if you decide 40
- If you want to deselect all marked items or select all items 40
- Indicates sequence of highlighted item and x are the order that the parameters are selected and will be displayed 40
- Not to press esc or use the left right scroll button to select no to continue pid selections 40
- Press the left button a message comes up to ask for your confirmation 40
- Press the ok button to view selected pids on screen 40
- The number x to the upper right corner of the screen 40
- Recording data 41
- Current test will be stored in a temporary cache 42
- Figure 5 0 42
- Figure 5 1 42
- Figure 5 2 42
- If data from previously tested vehicle is not erased data from 42
- Use the up down scroll button to select a memory location and press the ok button 42
- Use the up down scroll button to select a trigger mode and press the ok button 42
- Drive till a dtc is detected when dtc trigger is selected if no 44
- Dtcs are detected press esc to exit recording 44
- Figure 5 5 44
- Figure 5 6 44
- Indicates the maximum frames that can be recorded and the number of recorded frames 44
- The number x x to the upper right corner of the screen 44
- The scan tool keeps recording pid data until user presses the esc button selected memory location is full or it completes recording a message prompting to playback data shows on the screen 44
- Wait for dtc to trigger recording or press ok to start recording figure 5 6 44
- Playback data 47
- Viewing freeze frame data 48
- Retrieving i m readiness status 49
- A retrieve i m readiness status with one click i m 50
- Readiness key 50
- B retrieve i m readiness status in typical way 53
- O2 monitor test 56
- On board monitor test 57
- Advisory message will be displayed on the screen 59
- Figure 5 1 59
- Figure 5 2 59
- Figure 5 3 59
- For can equipped vehicles test selections can be as below 59
- From on board mon test menu use the up down scroll button to select a test to view and press the ok button or use the left right scroll button to view previous next screen of test items 59
- If the vehicle under test does not support the mode an 59
- Figure 5 4 60
- Figure 5 5 60
- Figure 5 6 60
- Note if the on board monitor test failed this monitor item will be red color just by the text color you may easily find out which system is at fault 60
- Use the up down scroll button to select the desired monitor from on board mon test menu and press the ok button 60
- View test data on screen 60
- Component test 61
- Viewing vehicle information 62
- Code breaker 64
- Modules present 64
- General information 66
- Ready test 66
- Ready test application 66
- As post repair diagnostic tool 67
- As pre check diagnostic tool 68
- Led and tone interpretation 69
- Audio tone interpretation 70
- Led interpretation 70
- Print data 71
- Limited one year warranty 73
- Service procedures 73
- Warranty and service 73
Похожие устройства
- Autel Autolink AL419 Руководство пользователя
- Autel Autolink AL619 Руководство пользователя
- Autel Autolink AL319 Руководство пользователя
- Autel Autolink AL301 Руководство пользователя
- Autel MaxiCheck DPF Reset Руководство пользователя
- Autel AutoLink AL539B Руководство пользователя
- Autel MaxiTPMS TS401 Руководство пользователя
- Autel MaxiCheck PRO Руководство пользователя
- Autel MaxiCheck Oil Light/Service Reset Руководство пользователя
- Autel MaxiCheck EPB Руководство пользователя
- Autel Maxivideo MV201 8.5 мм Руководство пользователя
- Autel Maxivideo MV400 5.5 мм Руководство пользователя
- Autel Maxivideo MV400 8.5 мм Руководство пользователя
- Coolfort CF-1216 Инструкция по эксплуатации
- Coolfort СF-1221 Инструкция по эксплуатации
- Coolfort CF-0525GY Инструкция по эксплуатации
- Cremesso Compact Automatic Burgundy Red Инструкция по эксплуатации
- Cremesso LM 600 Инструкция по эксплуатации
- Cuckoo CMC-CHSS1004F Инструкция по эксплуатации
- Defender Optimum MS-125 Nano Инструкция по эксплуатации