KSB Movitec LHV025/03 [9/60] High pressure pumps

KSB Movitec VS015/06 [9/60] High pressure pumps
Programme overview / selection tables
Table of fluids handled
The data refer to the chemical resistance of the materials. The relevant regulations / standards governing individual pump
applications have to be complied with.
If the operating conditions differ from the data given (e.g. mixed products) or if the fluids handled are not included in the table
below, please contact KSB.
Temperature ranges:
Reference temperature: +20 °C
For temperatures <0 °C: contact KSB.
For temperatures > +50 °C: check and observe the vapour pressure of the fluid handled.
Max. temperature = +120 °C, unless indicated otherwise.
Max. concentration = 100 % unless indicated otherwise.
Mechanical seal silicon carbide / carbon (Q1B): not suitable for fluids containing solid substances. This rule also covers
particles developing as a result of salt crystallisation at low fluid temperatures.
Mechanical seal tungsten carbide / tungsten carbide (U3U3): solids content max. 20 ppm (depending on particle size), with
the exception of corrosive fluids. Fluids with a higher solids content are not permitted (ppm = 1 mg/kg).
Caution: High temperatures will increase corrosion (reference temperature = +20 °C).
Under unfavourable conditions (high temperatures, deposits, long idle periods), chloride contents of more than 300 mg/l
may result in localised corrosion.
Selecting the design of pump and mechanical seal depending on the fluid to be handled
Fluid handled Movitec
Substance contained Max. per-
centage
T
max.
V VC VS LHS
[%] [°C] 13 14 15 16 18 13 14 15 16 18 23 13 14 15 16 18 17 19
Alum, acid-free ≤ 3 +50 - - - - - - - - - - - - - - - -
Alum, acid-free ≤ 3 +80 - - - - - - - - - - - - - - - - -
Alkaline solution, bottle
rinsing, max. 2 % sodium
hydroxide
≤ 100 +40 - - - - - - - - - - - - - - -
Alcohol
Butanol
≤ 100 +60 - - - - - - - - - - - - - -
Ethanol
≤ 100 +60 - - - - - - - - - - - - - -
Propanol
≤ 100 +80 - - - - - - - - - - - - - -
Spirits (40 % ethanol)
≤ 100 +60 - - - - - - - - - - - - - - - -
Wine (white, red) ≤ 100 +60 - - - - - - - - - - - -
Tartaric acid ≤ 100 +60 - - - - - - - - - - - - - - - - -
Ammonium bicarbonate ≤ 10 +40 - - - - - - - - - - - - - -
Aluminium sulphate, acid-free ≤ 5 +50 - - - - - - - - - - - - - - - -
Aluminium sulphate, acid-free ≤ 5 +60 - - - - - - - - - - - - - - - - -
Ammonium sulphate ≤ 20 +60 - - - - - - - - - - - - - - - -
Calcium acetate, acid-free ≤ 10 +60 - - - - - - - - - - - - - -
Calcium nitrate, acid-free ≤ 10 +60 - - - - - - - - - - - - - - - -
Ferric sulphate (II) ≤ 5 +80 - - - - - - - - - - - - - - - -
Water-oil emulsion (95 %,
5 %), free of solids
≤ 100 +80 - - - - - - - - - - - - - - -
Ethylene glycol base anti-
freeze, inhibited, closed
system
≤ 20 +110
10)
- -
10)
- -
10)
10)
- - - -
≤ 25 +110
10)
- -
10)
- -
10)
10)
- - - -
≤ 30 +110
10)
- -
10)
- -
10)
10)
- - - -
≤ 35 +110
10)
- -
10)
- -
10)
10)
- - - -
≤ 40 +110
10)
- -
10)
- -
10)
10)
- - - -
≤ 45 +110
10)
- -
10)
- -
10)
10)
- - - -
≤ 50 +110
10)
- -
10)
- -
10)
10)
- - - -
Ethylene glycol base anti-
freeze, inhibited, open system
≤ 20 +110
10)
- - - - - - - -
10)
- - - -
≤ 25 +110
10)
- - - - - - - -
10)
- - - -
≤ 30 +110
10)
- - - - - - - -
10)
- - - -
≤ 35 +110
10)
- - - - - - - -
10)
- - - -
10)
≤ 100 °C
High-pressure Pumps
High-pressure In-line Pumps
Movitec
9

Содержание

Скачать