Gigabyte G481-HA0 (rev. 200) [117/124] 8 bios post codes
![Gigabyte G481-HA0 (rev. 200) [117/124] 8 bios post codes](/views2/1681192/page117/bg75.png)
- 117 - BIOS Setup
5-8 BIOS POST Codes
5-8-1 AMI Standard - PEI
PEI_CORE_STARTED 0x10
PEI_CAR_CPU_INIT 0x11
PEI_CAR_NB_INIT 0x15
PEI_CAR_SB_INIT 0x19
PEI_MEMORY_SPD_READ 0x2B
PEI_MEMORY_PRESENCE_DETECT 0x2C
PEI_MEMORY_TIMING 0x2D
PEI_MEMORY_CONFIGURING 0x2E
PEI_MEMORY_INIT 0x2F
PEI_MEMORY_INSTALLED 0x31
PEI_CPU_INIT 0x32
PEI_CPU_CACHE_INIT 0x33
PEI_CPU_AP_INIT 0x34
PEI_CPU_BSP_SELECT 0x35
PEI_CPU_SMM_INIT 0x36
PEI_MEM_NB_INIT 0x37
PEI_MEM_SB_INIT 0x3B
PEI_DXE_IPL_STARTED 0x4F
DXE_CORE_STARTED 0x60
//Recovery
PEI_RECOVERY_AUTO 0xF0
PEI_RECOVERY_USER 0xF1
PEI_RECOVERY_STARTED 0xF2
PEI_RECOVERY_CAPSULE_FOUND 0xF3
PEI_RECOVERY_CAPSULE_LOADED 0xF4
//S3
PEI_S3_STARTED 0xE0
PEI_S3_BOOT_SCRIPT 0xE1
PEI_S3_VIDEO_REPOST 0xE2
PEI_S3_OS_WAKE 0xE3
DXE_CORE_STARTED 0x60
DXE_NVRAM_INIT 0x61
DXE_SBRUN_INIT 0x62
5-8-2 AMI Standard - DXE
DXE_CPU_INIT 0x63
DXE_NB_HB_INIT 0x68
DXE_NB_INIT 0x69
DXE_NB_SMM_INIT 0x6A
DXE_SB_INIT 0x70
DXE_SB_SMM_INIT 0x71
DXE_SB_DEVICES_INIT 0x72
Содержание
- User manual p.1
- G481 ha0 p.1
- Copyright p.2
- 2019 giga byte technology co ltd all rights reserved the trademarks mentioned in this manual are legally registered to their respective owners p.2
- Information in this manual is protected by copyright laws and is the property of gigabyte changes to the specifications and features in this manual may be made by gigabyte without prior notice no part of this manual may be reproduced copied translated transmitted or published in any form or by any means without gigabyte s prior written permission p.2
- In order to assist in the use of this product gigabyte provides the following types of documentation p.2
- For more information p.2
- Documentation classifications p.2
- Disclaimer p.2
- The following conventions are used in this user s guide p.3
- Conventions p.3
- Server warnings and cautions p.4
- Electrostatic discharge esd p.5
- Table of contents p.7
- Chapter 3 system hardware installation 3 p.7
- Chapter 2 system appearance 7 p.7
- Chapter 1 hardware installation 1 p.7
- 3 chipset setup menu 81 p.8
- 1 the main menu 53 5 2 advanced menu 56 p.8
- 1 motherboard components 49 4 2 jumper settings 50 p.8
- Chapter 5 bios setup 1 p.8
- Chapter 4 motherboard components 9 p.8
- 9 bios post beep code ami standard 123 p.9
- 6 boot menu 11 p.9
- 5 security menu 108 p.9
- 4 server management menu 101 p.9
- 114 5 7 save exit menu 115 5 8 bios post codes 117 p.9
- 10 bios recovery instruction 124 p.9
- This page intentionally left blank p.10
- Chapter 1 hardware installation p.11
- 1 installation precautions p.11
- 2 product specifications p.12
- G481 ha0 block diagram p.15
- Aspeed ast2500 p.15
- 3 system block diagram p.15
- 15 hardware installation p.15
- Skylake sp lga 3647 socket p0 p.15
- Pch intel c621 lewisburg p.15
- This page intentionally left blank p.16
- Chapter 2 system appearance p.17
- 1 front view p.17
- 2 rear view p.18
- No name color status description p.19
- 3 front panel buttons and leds p.19
- No name color status description p.20
- 5 rear system lan leds optional p.20
- 4 front system lan leds p.20
- 1 2 2 1 2 p.20
- Ac cord unplugged ac power lost but a second power supply in parallel still having ac input power power supply critical events that cause a shutdown such as otp ocp uvp ovp and fan failure p.21
- 7 hard disk drive leds p.21
- 6 power supply unit psu led p.21
- 21 system appearance p.21
- Off no ac power to all power supplies p.21
- Green on 12v output on and ok p.21
- Green blinking 2hz power supply firmware update p.21
- Green blinking 0 hz ac present only 12vsb on ps off or psu in smart standby mode p.21
- Color status description p.21
- Amber on p.21
- Amber blinking 0 hz power supply warning events where the power supply continues to operate such as high temperature high power high current slot fan p.21
- System appearance 22 p.22
- Red on error dimm missing p.22
- Off the memory module is operating normally p.22
- Memory status led p.22
- Color status description p.22
- 8 memory status led p.22
- Chapter 3 system hardware installation p.23
- 1 removing the top rear cover p.24
- 2 removing and installing the air duct p.25
- 3 removing the gpu fan module p.26
- 4 installing the gpu card optional p.27
- 5 installing the pcie card p.30
- 6 installing the cpu and heat sink p.32
- This motherboard provides 24 ddr4 memory sockets and supports six channel technology after the memory is installed the bios will automatically detect the specifications and capacity of the memory enabling four channel memory mode will be four times of the original memory bandwidth p.34
- System hardware installation 34 p.34
- Read the following guidelines before you begin to install the memory make sure that the motherboard supports the memory it is recommended that memory of the same capacity brand speed and chips be used always turn off the system and unplug the power cord from the power outlet before installing the memory to prevent hardware damage memory modules have a foolproof design a memory module can be installed in only one direction if you are unable to insert the memory switch the direction p.34
- 7 installing the memory p.34
- 7 1 six channel memory configuration p.34
- 7 3 dimm population rule p.35
- 7 2 installing a memory p.35
- Dimm density p.36
- Dimm capacity gb 1 slot per channel 2 slot per channel p.36
- Unbalanced mode configuration not recommended p.36
- 7 5 dimm optimal performance population table p.36
- System hardware installation 36 p.36
- 7 4 dimm population table p.36
- Speed mt s voltage v slot per channel spc dimm per channel dpc p.36
- 2666 2666 p.36
- Rdimm 3ds qrx4 8rx4 p.36
- Ranks per dimm and data width p.36
- Qrx4 8rx4 p.36
- N a n a 4h 128gb p.36
- N a n a 2h 64gb 4h 128gb p.36
- Lrdimm 3ds p.36
- Lrdimm p.36
- H 64gb p.36
- Gb 8gb p.36
- Gb 16gb p.36
- Dpc 1dpc 2dpc p.36
- 7 5 intel optane dcpmm dimm population rule p.37
- 37 system hardware installation p.37
- Thermal conditions for dcpmm dimm support the ambient temperature must be at or below 35 c the cascade lake cpu used must have a maximum tdp of 205w a maximum of 12 pcs 256g dcpmm may be installed p.37
- Rdimm dcpmm must be installed into cpu0 memory first you must install one rdimm into any slot 0 of cpu0 before installing the dcpmm e g a0 b0 c0 d0 e0 f0 the dcpmm must be installed into the dimm slot 1 next to the corresponding rdimm in slot 0 e g if rdimm is installed into dimm slot a0 the dcpmm must be installed into dimm slot a1 p.37
- 7 6 intel optane dcpmm dimm population rule p.37
- 8 installing the 2 hard disk drive p.38
- 9 installing the 3 hard disk drive p.39
- 10 replacing the system fan module p.40
- 11 removing the top front cover p.41
- 12 replacing the pcie raid card p.42
- 13 replacing the power supply p.44
- 14 replacing the lan module p.45
- System hardware installation 46 p.46
- 15 cable connections p.46
- 15 2 motherboard slimline 8i to pcie board p.46
- 15 1 motherboard cpu system power to pcie board p.46
- 15 4 mlan ncsi signal p.47
- 15 3 motherboard slimline 4i to pcie board p.47
- 47 system hardware installation p.47
- System hardware installation 48 p.48
- Nvme 6 7 p.48
- Nvme 4 5 p.48
- Nvme 2 3 p.48
- Nvme 0 1 p.48
- Hdd backplane board 2 hdd backplane board p.48
- Daughter board 1 daughter board 2 p.48
- 15 6 sata connections between hdd backplane board and daughter board p.48
- 15 5 motherboard to 2 hdd backplane board p.48
- Chapter 4 motherboard components p.49
- 1 motherboard components p.49
- Default p.50
- Clear cmos clr_cmos p.50
- Bios recovery bios_rcvr p.50
- 2 jumper settings p.50
- Password clear bios_pwd p.50
- Enable p.50
- Chapter 5 bios setup p.51
- Bios setup program function keys p.51
- Server management p.52
- Security p.52
- Save exit p.52
- Chipset p.52
- Advanced p.52
- 1 the main menu p.53
- 2 advanced menu p.56
- 2 1 iscsi configuration p.57
- 2 2 intel r virtual raid on cpu p.58
- 2 3 intel r i350 gigabit network connection p.59
- 2 4 vlan configuration p.61
- 2 5 intel r omni path hfi 100 series p.64
- 2 6 intel r ethernet controller x550 p.66
- 2 7 lsi sas3 mpt controller sas3008 p.68
- 2 8 trusted computing p.69
- 2 9 serial port console redirection p.70
- 2 10 sio configuration p.73
- 2 11 pci subsystem settings p.74
- 2 12 network stack configuration p.76
- 2 13 post report configuration p.77
- 2 14 nvme configuration p.78
- 2 15 usb configuration p.79
- 2 16 chipset configuration p.80
- 3 chipset setup menu p.81
- 3 1 processor configuration p.82
- 3 2 common refcode configuration p.84
- 3 3 upi configuration p.85
- 3 4 memory configuration p.86
- 3 5 iio configuration p.88
- 3 6 advanced power management configuration p.90
- 3 7 pch configuration p.93
- 3 8 miscellaneous configuration p.95
- 3 9 server me configuration p.96
- 3 10 runtime error logging p.97
- 3 11 power policy p.99
- 4 server management menu p.101
- 4 1 system event log p.103
- 4 2 view fru information p.104
- 4 3 bmc vlan configuration p.105
- 4 4 bmc network configuration p.106
- 4 5 ipv6 bmc network configuration p.107
- 5 security menu p.108
- 5 1 secure boot p.109
- 6 boot menu p.111
- 6 1 uefi network drive bbs priorities p.113
- 6 2 uefi application boot priorities p.114
- 7 save exit menu p.115
- 8 bios post codes p.117
- 8 2 ami standard dxe p.117
- 8 1 ami standard pei p.117
- 8 3 ami standard error p.119
- 8 5 intel upi error codes p.120
- 8 4 intel upi post codes p.120
- 8 7 intel mrc error codes p.121
- 8 6 intel mrc post codes p.121
- 8 9 intel pm post codes p.122
- 8 8 intel pm post codes p.122
- 9 bios post beep code ami standard p.123
- 9 2 dxe beep codes p.123
- 9 1 pei beep codes p.123
- 10 bios recovery instruction p.124
Похожие устройства
-
Gigabyte S260-NF1 (rev. 100)Руководство пользователя -
Gigabyte R281-T94 (rev. 100)Инструкция -
Gigabyte H261-NO0 (rev. 100)Инструкция -
Gigabyte H261-NO0 (rev. 100)Руководство пользователя GSM Server -
Gigabyte H261-NO0 (rev. 100)Руководство пользователя GSM Agent -
Gigabyte H261-NO0 (rev. 100)Руководство пользователя ErP Mode BIOS Setup -
Gigabyte H261-PC0 (rev. 100)Инструкция -
Gigabyte H261-PC0 (rev. 100)Руководство пользователя GSM Server -
Gigabyte H261-PC0 (rev. 100)Руководство пользователя GSM Agent -
Gigabyte H261-PC0 (rev. 100)Руководство пользователя ErP Mode BIOS Setup -
Gigabyte H261-Z61 (rev. A00)Инструкция -
Gigabyte H261-Z60 (rev. A00)Инструкция