4 - 3 Cooling Capacity Tables
2MXS40H2V1B
3D063455A
Cooling (50Hz 230V)
Combination
(Capacity)
Outdoor air
temp.
°CDB
Indoor air temperature: °CWB
14°C 16°C 18°C 19°C 22°C 24°C
TC PI TC PI TC PI TC PI TC PI TC PI
kW kW kW kW kW kW kW kW kW kW kW kW
2.0
10.0 2.68 0.42 2.79 0.43 2.90 0.44 2.96 0.45 3.12 0.46 3.24 0.47
12.0 2.64 0.43 2.75 0.44 2.86 0.45 2.91 0.46 3.08 0.47 3.19 0.48
15.0 2.57 0.45 2.68 0.46 2.79 0.47 2.85 0.47 3.01 0.49 3.12 0.50
18.0 2.50 0.46 2.61 0.47 2.72 0.48 2.78 0.49 2.95 0.50 3.06 0.51
20.0 2.46 0.47 2.57 0.48 2.68 0.49 2.74 0.50 2.90 0.51 3.01 0.52
22.0 2.41 0.48 2.52 0.49 2.64 0.50 2.69 0.51 2.86 0.52 2.97 0.53
25.0 2.35 0.50 2.46 0.51 2.57 0.52 2.62 0.53 2.79 0.54 2.90 0.55
28.0 2.28 0.52 2.39 0.53 2.50 0.54 2.56 0.54 2.72 0.56 2.83 0.57
32.0 2.19 0.55 2.30 0.56 2.41 0.57
2.47 0.57
2.63 0.58 2.74 0.59
35.0 2.12 0.57 2.23 0.58 2.34 0.59 2.40 0.59 2.57 0.60 2.68 0.61
40.0 2.01 0.60 2.12 0.61 2.23 0.62
2.29 0.63
2.45 0.64 2.56 0.65
43.0 1.94 0.63 2.06 0.64 2.17 0.65 2.22 0.65 2.39 0.66 2.50 0.67
46.0 1.88 0.65 1.99 0.66 2.10 0.67 2.15 0.67 2.32 0.69 2.43 0.70
2.5
10.0 3.22 0.56 3.49 0.60 3.63 0.62 3.70 0.62 3.91 0.64 4.04 0.66
12.0 3.22 0.58 3.44 0.62 3.57 0.63 3.64 0.64 3.85 0.66 3.99 0.67
15.0 3.21 0.62 3.35 0.64 3.49 0.65 3.56 0.66 3.77 0.67 3.90 0.69
18.0 3.13 0.64 3.27 0.66 3.41 0.67 3.47 0.68 3.68 0.70 3.82 0.71
20.0 3.07 0.66 3.21 0.67 3.35 0.68 3.42 0.69 3.63 0.71 3.76 0.72
22.0 3.02 0.67 3.16 0.69 3.29 0.70 3.36 0.71 3.57 0.73 3.71 0.74
25.0 2.93 0.70 3.07 0.71 3.21 0.72 3.28 0.73 3.49 0.75 3.62 0.76
28.0 2.85 0.72 2.99 0.74 3.13 0.75 3.20 0.76 3.40 0.78 3.54 0.79
32.0 2.74 0.76 2.88 0.77 3.01 0.79
3.08 0.79
3.29 0.81 3.43 0.83
35.0 2.65 0.79 2.79 0.80 2.93 0.81 3.00 0.82 3.21 0.84 3.35 0.85
40.0 2.51 0.84 2.65 0.85 2.79 0.86
2.86 0.87
3.07 0.89 3.21 0.90
43.0 2.43 0.87 2.57 0.88 2.71 0.90 2.78 0.90 2.98 0.92 3.12 0.94
46.0 2.35 0.90 2.49 0.92 2.62 0.93 2.69 0.94 2.90 0.96 3.04 0.97
3.5
10.0 3.29 0.67 4.04 0.85 4.84 1.06 4.93 1.07 5.21 1.10 5.39 1.13
12.0 3.29 0.70 4.04 0.89 4.76 1.08 4.86 1.09 5.13 1.13 5.32 1.15
15.0 3.29 0.74 4.04 0.95 4.65 1.12 4.75 1.13 5.02 1.16 5.21 1.18
18.0 3.29 0.79 4.04 1.01 4.54 1.15 4.63 1.16 4.91 1.20 5.09 1.22
20.0 3.29 0.83 4.04 1.06 4.47 1.18 4.56 1.19 4.84 1.22 5.02 1.25
22.0 3.29 0.87 4.04 1.11 4.39 1.20 4.48 1.22 4.76 1.25 4.94 1.27
25.0 3.29 0.93 4.04 1.20 4.28 1.25 4.37 1.26 4.65 1.29 4.83 1.31
28.0 3.29 1.01 3.98 1.27 4.17 1.29 4.26 1.30 4.54 1.33 4.72 1.36
32.0 3.29 1.12 3.84 1.33 4.02 1.35
4.11 1.36
4.39 1.40 4.57 1.42
35.0 3.29 1.21 3.72 1.38 3.91 1.40 4.00 1.41 4.28 1.45 4.46 1.47
40.0 3.29 1.40 3.54 1.46 3.72 1.49
3.81 1.50
4.09 1.53 4.27 1.55
43.0 3.24 1.50 3.40 1.50 3.56 1.50 3.63 1.50 3.85 1.50 3.98 1.50
46.0 2.82 1.30 2.95 1.30 3.08 1.30 3.15 1.30 3.33 1.30 3.45 1.30
Combination
(Capacity)
Outdoor air
temp.
°CDB
Indoor air temperature: °CWB
14°C 16°C 18°C 19°C 22°C 24°C
TC PI TC PI TC PI TC PI TC PI TC PI
kW kW kW kW kW kW kW kW kW kW kW kW
2.0 + 2.0
10.0 4.58 0.81 4.77 0.83 4.96 0.85 5.05 0.86 5.34 0.89 5.53 0.90
12.0 4.51 0.83 4.69 0.85 4.88 0.87 4.98 0.88 5.26 0.90 5.45 0.92
15.0 4.39 0.86 4.58 0.88 4.77 0.89 4.86 0.90 5.15 0.93 5.34 0.95
18.0 4.28 0.89 4.47 0.91 4.65 0.92 4.75 0.93 5.03 0.96 5.22 0.98
20.0 4.20 0.91 4.39 0.93 4.58 0.94 4.67 0.95 4.96 0.98 5.14 1.00
22.0 4.12 0.93 4.31 0.95 4.50 0.96 4.60 0.97 4.88 1.00 5.07 1.02
25.0 4.01 0.96 4.20 0.98 4.39 1.00 4.48 1.01 4.77 1.03 4.95 1.05
28.0 3.90 1.00 4.08 1.02 4.27 1.03 4.37 1.04 4.65 1.07 4.84 1.09
32.0 3.74 1.05 3.93 1.06 4.12 1.08
4.21 1.09
4.50 1.12 4.69 1.14
35.0 3.63 1.09 3.82 1.10 4.01 1.12 4.10 1.13 4.38 1.16 4.57 1.18
40.0 3.44 1.16 3.63 1.17 3.81 1.19
3.91 1.20
4.19 1.23 4.38 1.25
43.0 3.32 1.20 3.51 1.22 3.70 1.24 3.79 1.24 4.08 1.27 4.27 1.29
46.0 3.21 1.25 3.40 1.26 3.59 1.28 3.68 1.29 3.93 1.30 4.08 1.30
2.0 + 2.5
10.0 4.69 0.86 4.89 0.88 5.08 0.89 5.18 0.90 5.47 0.93 5.66 0.95
12.0 4.62 0.87 4.81 0.89 5.00 0.91 5.10 0.92 5.39 0.95 5.58 0.97
15.0 4.50 0.90 4.69 0.92 4.89 0.94 4.98 0.95 5.27 0.98 5.47 1.00
18.0 4.38 0.93 4.57 0.95 4.77 0.97 4.86 0.98 5.16 1.01 5.35 1.03
20.0 4.30 0.96 4.50 0.97 4.69 0.99 4.79 1.00 5.08 1.03 5.27 1.05
22.0 4.22 0.98 4.42 1.00 4.61 1.02 4.71 1.03 5.00 1.05 5.19 1.07
25.0 4.11 1.01 4.30 1.03 4.49 1.05 4.59 1.06 4.88 1.09 5.07 1.11
28.0 3.99 1.05 4.18 1.07 4.38 1.09 4.47 1.10 4.76 1.13 4.96 1.15
32.0 3.83 1.10 4.03 1.12 4.22 1.14
4.32 1.15
4.61 1.18 4.80 1.20
35.0 3.72 1.14 3.91 1.16 4.10 1.18 4.20 1.19 4.49 1.22 4.68 1.24
40.0 3.52 1.22 3.71 1.24 3.91 1.25
4.00 1.26
4.29 1.29 4.49 1.31
43.0 3.40 1.26 3.60 1.28 3.79 1.30 3.89 1.31 4.18 1.34 4.37 1.36
46.0 3.27 1.30 3.43 1.30 3.58 1.30 3.66 1.30 3.88 1.30 4.02 1.30
2.0 + 3.5
10.0 4.92 0.94 5.12 0.96 5.32 0.98 5.42 0.99 5.73 1.03 5.93 1.05
12.0 4.84 0.96 5.04 0.98 5.24 1.00 5.34 1.01 5.65 1.05 5.85 1.07
15.0 4.71 0.99 4.92 1.02 5.12 1.04 5.22 1.05 5.52 1.08 5.73 1.10
18.0 4.59 1.03 4.79 1.05 5.00 1.07 5.10 1.08 5.40 1.11 5.60 1.13
20.0 4.51 1.05 4.71 1.07 4.91 1.09 5.01 1.10 5.32 1.14 5.52 1.16
22.0 4.43 1.08 4.63 1.10 4.83 1.12 4.93 1.13 5.24 1.16 5.44 1.18
25.0 4.30 1.12 4.51 1.14 4.71 1.16 4.81 1.17 5.11 1.20 5.32 1.22
28.0 4.18 1.16 4.38 1.18 4.59 1.20 4.69 1.21 4.99 1.24 5.19 1.26
32.0 4.02 1.21 4.22 1.23 4.42 1.26
4.52 1.27
4.83 1.30 5.03 1.32
35.0 3.89 1.26 4.10 1.28 4.30 1.30 4.40 1.31 4.70 1.34 4.91 1.36
40.0 3.69 1.34 3.89 1.36 4.09 1.38
4.20 1.39
4.50 1.42 4.70 1.44
43.0 3.57 1.39 3.77 1.41 3.97 1.43 4.07 1.44 4.38 1.47 4.58 1.50
46.0 3.22 1.30 3.37 1.30 3.52 1.30 3.59 1.30 3.80 1.30 3.94 1.30
NOTES SYMBOLS
1 Capacities are based on the following conditions.
Corresponding refrigerant piping length: 5.0m
Level difference: 0m
2 The bold line is indicated the standard condition.
3 The above is the value for connecting with the following indoor units.
2.0, 2.5, 3.5 kW class; wall mounted ATX-G, ATXS-J, FTX-J (GSI-S)series.
TC: Total capacity (kW)
PI: Power input (kW)