Daikin 2MXS40H2V1B [8/32] Capacity tables

Daikin 2MXS40H2V1B [8/32] Capacity tables
Outdoor Unit • Multi model application • MXS-H
Split - Sky Air
®
• Outdoor Unit
6
4 Capacity tables
4 - 1 Combination Table
2MXS40H2V1B
Cooling (50Hz 230V)
Outdoor unit
Combination of
indoor unit
Capacity of each indoor unit
Each capacity (kW) Total capacity (kW) Total input (W) Total current (A) Power factor (%)
A room B room Rating (min ~ max) Rating (min ~ max) Rating (min ~ max) Rating
2MXS40H2V1B
2.0 2.00 - 2.00 1.50 ~ 2.40 440 330 ~ 570 2.0 1.5 ~ 2.6 94
2.5 2.50 - 2.50 1.50 ~ 3.00 610 330 ~ 800 2.8 1.5 ~ 3.7 94
3.5 3.50 - 3.50 1.50 ~ 4.00 1050 330 ~ 1360 4.8 1.5 ~ 6.2 95
2.0 + 2.0 2.00 2.00 4.00 1.75 ~ 4.20 1040 310 ~ 1120 4.8 1.4 ~ 5.2 94
2.0 + 2.5 1.85 2.15 4.00 1.75 ~ 4.30 1030 310 ~ 1170 4.8 1.4 ~ 5.4 94
2.0 + 3.5 1.75 2.25 4.00 1.75 ~ 4.50 1000 310 ~ 1230 4.6 1.4 ~ 5.7 94
2.5 + 2.5 2.00 2.00 4.00 1.75 ~ 4.40 1020 310 ~ 1230 4.7 1.4 ~ 5.7 94
2.5 + 3.5 1.80 2.20 4.00 1.75 ~ 4.60 990 310 ~ 1310 4.6 1.4 ~ 6.1 94
Heating (50Hz 230V)
Outdoor unit
Combination of
indoor unit
Capacity of each indoor unit
Each capacity (kW) Total capacity (kW) Total input (W) Total current (A) Power factor (%)
A room B room Rating (min ~ max) Rating (min ~ max) Rating (min ~ max) Rating
2MXS40H2V1B
2.0 3.00 - 3.00 1.10 ~ 3.70 820 260 ~ 1230 3.8 1.2 ~ 5.7 94
2.5 3.40 - 3.40 1.10 ~ 4.10 1020 260 ~ 1480 4.7 1.2 ~ 6.8 95
3.5 3.80 - 3.80 1.10 ~ 4.40 1280 260 ~ 1720 5.9 1.2 ~ 7.9 95
2.0 + 2.0 2.10 2.10 4.20 1.40 ~ 4.60 960 250 ~ 1120 4.4 1.1 ~ 5.1 95
2.0 + 2.5 2.10 2.30 4.40 1.40 ~ 4.70 1040 250 ~ 1170 4.7 1.1 ~ 5.3 96
2.0 + 3.5 2.00 2.40 4.40 1.40 ~ 4.70 1000 240 ~ 1120 4.5 1.1 ~ 5.1 96
2.5 + 2.5 2.20 2.20 4.40 1.40 ~ 4.70 1030 250 ~ 1160 4.7 1.1 ~ 5.3 96
2.5 + 3.5 2.05 2.35 4.40 1.40 ~ 4.70 990 240 ~ 1110 4.5 1.1 ~ 5.0 96
3D063422A
NOTES
1. Cooling capacity is based on 27°C DB/19°C WB (Indoor temperature), 35°C DB (Outdoor temperature).
Heating capacity is based on 20°C DB (Indoor temperature), 7°C DB/6°C WB (Outdoor temperature).
2. It’s possible to connect an indoor unit up to 6.0 kW.
3. It is impossible to connect the indoor unit for one room only.
4. The above is the value for connecting with the following indoor units.
2.0, 2.5, 3.5 kW class; Wall mounted ATXS-G, FTXS-J (NW-S2) series.
2MXS40H2V1B
Cooling (50Hz 230V)
Outdoor unit
Combination of
indoor unit
Capacity of each indoor unit
Each capacity (kW) Total capacity (kW) Total input (W) Total current (A) Power factor (%)
A room B room Rating (min ~ max) Rating (min ~ max) Rating (min ~ max) Rating
2MXS40H2V1B
2.0 2.00 - 2.00 1.45 ~ 2.40 450 320 ~ 590 2.1 1.5 ~ 2.7 94
2.5 2.50 - 2.50 1.45 ~ 3.00 620 320 ~ 820 2.9 1.5 ~ 3.8 94
3.5 3.50 - 3.50 1.45 ~ 4.00 1080 320 ~ 1410 4.9 1.5 ~ 6.5 95
2.0 + 2.0 2.00 2.00 4.00 1.65 ~ 4.10 1090 300 ~ 1130 5.0 1.4 ~ 5.2 94
2.0 + 2.5 1.85 2.15 4.00 1.65 ~ 4.20 1080 300 ~ 1190 5.0 1.4 ~ 5.5 94
2.0 + 3.5 1.75 2.25 4.00 1.65 ~ 4.40 1060 300 ~ 1310 4.9 1.4 ~ 6.1 94
2.5 + 2.5 2.00 2.00 4.00 1.65 ~ 4.30 1070 300 ~ 1240 4.9 1.4 ~ 5.7 94
2.5 + 3.5 1.80 2.20 4.00 1.65 ~ 4.50 1050 300 ~ 1350 4.9 1.4 ~ 6.2 94
Heating (50Hz 230V)
Outdoor unit
Combination of
indoor unit
Capacity of each indoor unit
Each capacity (kW) Total capacity (kW) Total input (W) Total current (A) Power factor (%)
A room B room Rating (min ~ max) Rating (min ~ max) Rating (min ~ max) Rating
2MXS40H2V1B
2.0 3.00 - 3.00 1.20 ~ 3.70 850 290 ~ 1270 3.9 1.3 ~ 5.9 94
2.5 3.40 - 3.40 1.20 ~ 4.10 1060 290 ~ 1520 4.9 1.3 ~ 7.0 95
3.5 3.80 - 3.80 1.20 ~ 4.40 1290 290 ~ 1730 5.9 1.3 ~ 7.9 95
2.0 + 2.0 2.10 2.10 4.20 1.50 ~ 4.60 1010 270 ~ 1170 4.7 1.2 ~ 5.4 95
2.0 + 2.5 2.10 2.30 4.40 1.50 ~ 4.70 1080 270 ~ 1210 5.0 1.2 ~ 5.5 96
2.0 + 3.5 2.00 2.40 4.40 1.50 ~ 4.70 1060 260 ~ 1190 4.9 1.2 ~ 5.4 96
2.5 + 2.5 2.20 2.20 4.40 1.50 ~ 4.70 1070 270 ~ 1200 4.9 1.2 ~ 5.4 96
2.5 + 3.5 2.05 2.35 4.40 1.50 ~ 4.70 1050 260 ~ 1180 4.8 1.2 ~ 5.3 96
3D063423A
NOTES
1. Cooling capacity is based on 27°C DB/19°C WB (Indoor temperature), 35°C DB (Outdoor temperature).
Heating capacity is based on 20°C DB (Indoor temperature), 7°C DB/6°C WB (Outdoor temperature).
2. It’s possible to connect an indoor unit up to 6.0 kW.
3. It is impossible to connect the indoor unit for one room only.
4. The above is the value for connecting with the following indoor units.
2.0, 2.5, 3.5 kW class; Wall mountes ATX-G, ATX-J, FTX-J (GSI-S) series.