(5) Filter Check Indicator
The filter check indicator located at the center of the unit will indicate the time for cleaning the air filters.
The indicator will indicate an appropriate cleaning time depending on the environment (dusty place or not). This will prevent you
from forgetting filter cleaning and also prevent performance drop that might be caused by using clogged filters and wasteful use
of electricity by approximately 8 %.
(Contents of indication)
Sensed by the operation hours and the fan motor voltage.
1) Filter clogging
Indicates the earlier one of the above 1) or 2).
This indicator utilizes the characteristic that the fan motor voltage drops as the crossflow fan gets clogged. It does not detects
the amount of filter clogging.
Note :
When the power supply is reset, the accumulated operation hour is not reset.
After cleaning and mounting the filters, press the reset button located inside the panel of the unit.
(6) Air Purification Filter
The air purification filter uses static electricity to attract and remove small particles as small as 0.01 micron from the air, such as
cigarette smoke and pollens. The filter has pleats that minimize pressure loss and offer high dust collecting efficiency, and features
a mold-resisting treatment.
The filter is also equipped with a net-type activated charcoal deodorizing filter to eliminate odor-causing particles.
The filter should be replaced about once every three months.
168 hours
336 hours
Definite
336 hours
2) accumulated operation hours
Control panel
CLEANING LAMP
RESET button
Push this button to turn the
CLEANING lamp off.
Cleaning lamp reset