Daikin RZQ140B7W1B [315/326] Removal of pc board ass y 2

Daikin RZQ125B7W1B [315/326] Removal of pc board ass y 2
ESIE05-03 Disassembly and Maintenance: Outdoor Units
Part 5 Disassembly and Maintenance 5–11
3
5
1
5
1.2.5 Removal of PC Board Ass'y (2)
Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.
Procedure
Step Procedure Points
2 Remove the PC board (for
inverter use)
1
2
Disconnect all
connectors.
Unscrew the three
screws that fix the
mounting plate of
electrical components
(for control use).
Disengage the hooks in
two places to remove the
mounting plate of
electrical components
(for control use).
3 In order to remove the
PC board ass'y (for
inverter use), unscrew a
single screw.
Note:
The plastic casing and the PC board are bonded to
each other. Therefore, for the replacement of these
parts, replace by a set of the PC board ass'y.
Hooks
Plastic casing
PC board
Fixing screw
ESIE05-03.book Page 11 Wednesday, April 6, 2005 4:09 PM