Aten PE6216 [11/76] Introduction
![Aten PE6324 [11/76] Introduction](/views2/1978030/page11/bgb.png)
1
Chapter 1
Introduction
Overview
ATEN PE6216 / PE6324 eco PDUs are intelligent PDUs that contain 16 or 24
AC outlets for convenient and efficient data center power usage management,
and are available in various IEC or NEMA socket configurations.
They provide secure, centralized, intelligent, power management (power on,
off, cycle) for data center IT equipment (servers, storage systems, KVM
switches, network devices, serial data devices, etc.), as well as the ability to
monitor the center's health environment via sensors*. The basic characteristics
of each model are shown in the table on page 3.
ATEN eco PDUs offer remote power control combined with real-time power
measurement - allowing you to control and monitor the power status of devices
attached to the PDUs, either at the PDU device or outlet level, from practically
any location via a TCP/IP connection.
The power status of each outlet can be set individually, allowing users to switch
each device On/Off. The eco PDU also offers comprehensive power analysis
reports which can separate departments and locations, providing precise
measurements of current, voltage, power and watt-hour in a real-time display.
Installation and operation is fast and easy: plugging cables into their
appropriate ports and user-friendly browser-based configuration and
management is all that is entailed. Since the eco PDU firmware is upgradeable
over the Net, you can stay current with the latest functionality improvements
simply by downloading updates from our website as they become available.
ATEN eco PDU supports any 3rd party V1, V2, V3 SNMP Manager Software
and ATEN eco DC (eco PDU manager web GUI). eco DC provides you with
an easy method for managing multiple devices, offering an intuitive and user-
friendly graphical user interface that allows you to configure a PDU device and
monitor power status of the equipment connected to it.
With its advanced security features and ease of operation, the eco PDU is the
most convenient, most reliable, and most cost effective way to remotely
manage power access for multiple computer installations and allocate power
resources in the most efficient way possible.
Содержание
- Pe6216 pe6324 1
- User manual 1
- Compliance statements 2
- Pe device safety notice 3
- Online registration 4
- Telephone support 4
- User information 4
- User notice 4
- Package contents 5
- Product information 5
- Basic operation and first time setup 6
- Chapter 1 6
- Chapter 2 6
- Chapter 3 6
- Contents 6
- Hardware setup 6
- Introduction 6
- Appendix 7
- Browser operation 7
- Chapter 4 7
- About this manual 8
- Conventions 9
- This manual uses the following conventions 9
- This page intentionally left blank 10
- Chapter 1 11
- Introduction 11
- Overview 11
- Bank yes 13
- Chapter 1 introduction 13
- Comparison chart 13
- Model inlet cord outlets 13
- Note for the complete specifications of individual models please referto 13
- Pdu yes 13
- Pe6216a iec 60320 c20 16 14 x nema 5 15r 13
- Pe6216b 14 x iec 60320 c13 13
- Pe6216g 13
- Pe6324b nema l6 30p 24 21 x iec 60320 c13 13
- Pe6324g iec 60309 21 x iec 60320 c13 13
- Specifications page 62 13
- X iec 60320 c19 13
- X nema 5 20r 13
- Features 14
- Operation 14
- Power distribution 14
- Remote access 14
- Eco dc energy management web gui 15
- Management 15
- Security 15
- Requirements 16
- Cable holders 17
- Optional accessories 17
- Sensor management 17
- Sensors 17
- Components 18
- Pe6216a front view 18
- Note holes for aten lok u plug cable holders are located around the 19
- Outlets see securing the cables page 19 for further information 19
- Pe6216b pe6216g front view 20
- Note holes for aten lok u plug cable holders are located around the 21
- Outlets see securing the cables page 19 for further information 21
- Pe6324b pe6324g front view 22
- Note holes for aten lok u plug cable holders are located around the 23
- Outlets see securing the cables page 19 for further information 23
- Readout section 24
- Before you begin 25
- Chapter 2 25
- Hardware setup 25
- Rack mounting 25
- For safety reasons the eco pdu should not be installed with the power sockets facing directly up or down and thus should only be installed with the power sockets facing out from a vertical position as shown below 26
- Pdu placement 26
- Installation 27
- Securing the cables 29
- Securing the sensors 30
- Basic operation and first time setup 31
- Browser 31
- Chapter 3 31
- Eco dc 31
- Operation methods 31
- First time setup 32
- Network configuration 33
- Changing the administrator login 34
- Moving on 34
- Browser operation 35
- Chapter 4 35
- Logging in 35
- The eco pdu main page 36
- Page components 37
- The web page screen components are described in the table below 37
- Connections 38
- Outlet access 38
- Pdu status 39
- Outlet status 40
- Sidebar 40
- Configuration 41
- Continues on next page 41
- The configuration page is used to configure the settings of the eco pdu at the individual power outlet level 41
- This page lets you set up the power management configuration for the selected outlet the meanings of the field headings are given in the following table 41
- Continued from previous page 42
- When you have finished making your configuration settings click save 42
- Administrator information 43
- User management 43
- Click save to save your settings 44
- Key in a name and password in the name and password fields 44
- Note values must be entered in both the name and password fields in 44
- Order to enable an account 44
- Select the user type in the management drop down menu 44
- Set the management field to enable 44
- Set the outlet by outlet permissions of the user in the outlet field 44
- The various options are explained in more detail in the following table 44
- To add a user do the following 44
- User information 44
- The system log event list 45
- Device configuration 46
- Device management 46
- General 46
- The device management page allows administrators and users with device management permission to configure and control overall eco pdu operations 46
- This page presents information about the selected device as described in the following sections 46
- Service ports 47
- Ipv4 configuration 48
- Event notification 49
- Syslog server 51
- Date time 52
- Time zone 52
- Finishing up 53
- Manual input 53
- Network time 53
- Login failures 54
- Security 54
- Working mode 54
- Account policy 55
- Check a policy and enter the required information in the appropriate fields 55
- The account policy section governs policies in regard to usernames and passwords 55
- Login string ip filter mac filter 56
- Adding filters 57
- Deleting filters 58
- Ip filter mac filter conflict 58
- Modifying filters 58
- Authentication authorization 59
- Radius settings 59
- Generating a self signed certificate 61
- Importing the private certificate 61
- Obtaining a ca signed ssl server certificate 61
- Private certificate 61
- A description of the items shown in this panel are given in the table below 62
- Firmware file 62
- Maintenance 62
- The maintenance function is used to upgrade the eco pdu s firmware and to backup and restore the device s configuration settings 62
- When you click the maintenance tab the display opens with the firmware upgrade menu page which looks similar to the one below 62
- Backup 64
- Backup restore 64
- Restore 64
- Appendix 65
- General 65
- Safety instructions 65
- Rack mounting 68
- Securing the power cables 68
- The eco pdu s main power cord 68
- International 69
- North america 69
- Technical support 69
- Ip address determination 70
- Method 1 70
- Method 2 71
- Method 3 71
- Eco pdu series user manual 72
- Pe6216a 72
- Specifications 72
- Appendix 73
- Pe6216b pe6324b 73
- Eco pdu series user manual 74
- Pe6216g pe6324g 74
- Administrator login failure 75
- Limited warranty 76
Похожие устройства
- Aten PE6324 RESTful API для релейного управления
- Aten PE6324 Удаленное управление терминалом
- Aten PE6324 Инструкция
- Aten PE6324 Краткое руководство по установке
- Aten PE6324 Руководство пользователя
- Aten PE6208AV RESTful API для релейного управления
- Aten PE6208AV Краткое руководство по установке v2
- Aten PE6208AV Краткое руководство по установке v1
- Aten PE6208AV Руководство пользователя
- Aten PG95230 Руководство пользователя
- Aten PG95230 Краткое руководство по установке
- Aten PG95330 Краткое руководство по установке
- Aten PG95330 Руководство пользователя
- Aten PE5224TA Краткое руководство по установке
- Aten PE5224TA Руководство пользователя
- Aten PE5221T Краткое руководство по установке
- Aten PE5221T Руководство пользователя
- Aten PE5342TG Краткое руководство по установке
- Aten PE5342TG Руководство пользователя
- Aten PE5340SL Краткое руководство по установке