DIP-20 - Principles of Operation
Note: The default timeout for audio switching when the input signal is lost is
five seconds. This can be changed using either P3000 commands or the Web
pages.
6.4 VGA Phase Shift
To minimize phase on the input VGA signal, the VGA sampling phase can be
shifted using the following methods:
A long press on the PC IN select button on the front panel.
Each long press steps the phase shift up one step, starting from 0 and
going to 31. When set to 31, another long press steps the shift to 0
A remote, contact-closure switch connected to pins 1 and G of the
Remote terminal block.
Each long press steps the phase shift up one step, starting from 0 and
going to 31. When set to 31, another long press steps the shift to 0
Using the Web pages, (see Section 9.1)
Protocol 3000 commands over RS-232 (see Section 12)