Zyxel IES-5112 [157/1156] Chapter 5 alarm screens

Zyxel IES-5112 [157/1156] Chapter 5 alarm screens
Chapter 5 Alarm Screens
Management Switch Card User’s Guide
157
VOP_NO_FREE_DSP_CHAN
NEL
INFO X A VOP card’s DSP channels were all in
use so the VOP was not able to handle
another call. This could be caused by the
VOP card’s DSP processing many
conference calls.
VOP_MC_MISSING CRITICAL X The signaling VOP card cannot detect the
media VOP card.
VOP_SC_MISSING CRITICAL X The media VOP card cannot detect the
signaling VOP card.
VOP_TERMNAME_DUP INFO X The VOP detected a duplicate terminal
name.
VOP_NO_PROTECTION INFO X The active SC cannot detect the standby
SC.
VOP_PROTECTION_SWITC
H
CRITICAL X The standby SC changed to active
because it could not detect the active
SC.
VOP_DROP_CALL INFO X The VOP dropped a call because the
burst calls or average calls exceeded the
BHCA setting.
Intf (Interface)
CFM_ERROR minor X A connectivity fault is detected by CFM
loopback or linktrace test.
LLDP_REMOTE_CHANGE minor A remote LLDP’s data changed.
IMA
GROUP_STARTUP_FE minor X The remote IMA group is up.
GROUP_CONF_ABORT major X The remote IMA tries to use
unacceptable configuration parameters.
GROUP_CONF_ABORT_FE minor X The remote IMA reports unacceptable
configuration parameters.
GROUP_INSUFF_LINK major X When less than PTx transmit or PRx
receive links are Active
GROUP_INSUFF_LINK_FE minor X The remote IMA reports that less than
PTx transmit or PRx receive links are
Active
GROUP_BLOCKED_FE minor X The remote IMA reports that an IMA
group is disabled
GROUP_TIMING_MISMATC
H
minor X The remote IMAs transmit clock mode is
different than a local IMA line card’s
transmit clock mode
LINK_LIF major X A Loss of IMA Frame (LIF) defect was
detected by the local IMA line card.
LINK_LODS minor X A Link Out of Delay Synchronization
(LODS) defect was detected by the local
IMA line card.
LINK_RFI minor X A Remote Failure Indicator (RFI) defect
was detected by the local IMA line card.
LINK_TX_MIS_CONN minor X A transmit link is not connected to the
same remote IMA device as the other
transmit links in the group.
Table 60 Alarm Descriptions (continued)
ALARM SEVERITY MSC ALC SLC VLC VOP IMA DESCRIPTION

Содержание