Zyxel IES-5112 [823/1156] Port pvc show command

Zyxel IES-6000 [823/1156] Port pvc show command
Chapter 31 port Commands
Management Switch Card User’s Guide
823
This command creates or modifies a PVC setting.
The following example sets a PVC on DSL port 5 on the line card in slot 2 with VPI 8, VCI 35, the
DEFVAL profile, default VID 2 and priority 3.
31.27.5 port pvc show Command
Syntax:
port pvc show <slot>|<slot-port>|<slot-port-vpi/vci> [detail]
where
This command displays the runtime configured virtual channels for the specified DSL port(s).
The following example displays the virtual channels of DSL port 5 on the line card in slot 2.
31.27.6 port pvc usratelimit enable Command
Syntax:
port pvc usratelimit enable <pvc>
This command activates upstream rate limiting on the PVC. The following example activates
upstream rate settings on the PVC (0/33 of port 1 on the line card in slot 5).
<pvid>
=
Set a default VID (1 to 4094) for the channel. The channel can only forward
frames with this VLAN ID. The system would drop any frames received from the
subscriber that are tagged with another VLAN ID.
Each PVC must have a unique VID since the system forwards traffic back to the
subscribers based on the VLAN ID.
<priority>
=
Set an IEEE 802.1p default priority (0 to 7) to add to incoming frames without a
(IEEE 802.1p) priority tag.
ras> port pvc set 2-5-8/35 DEFVAL vcmux 2 3
<slot-port-
vpi/vci>
=
The slot and port(s) and VPI/VCI of the PVC.
[detail]
=
Displays in depth information about the runtime configured virtual channels.
ras> port pvc show 2-5
pvc type mux pvid pri mvlan profile
--------------- ------- ----- ------ ---- ----- ------------
2-5-0/33 bridged llc 1 0 - DEFVAL
2-5-8/35 bridged vcmux 2 3 - DEFVAL
ras> port pvc usratelimit enable 5-1-0/33

Содержание