Zyxel IES-5112 [825/1156] Port shdsl commands

Zyxel IES-5106 [825/1156] Port shdsl commands
Chapter 31 port Commands
Management Switch Card User’s Guide
825
This command adds a PVC to a VLAN or removes a PVC from a VLAN. It also sets whether the PVC
sends frames with or without a VLAN tag.
The following example adds the PVC on DSL port 5 on the line card in slot 7 with VPI 8 and VCI 35
to VLAN 23.
31.28 port shdsl Commands
Use the port shdsl commands to configure the subscriber SHDSL ports.
31.28.1 port shdsl alarmprof Command
Syntax:
port shdsl alarmprof <slot-port> span|stuc|stur|* <alarmprofile>
where
This command sets the specified SHDSL port(s) or end point(s) to use an alarm profile.
The following example sets SHDSL port 8 on the line card in slot 6 to use the SESalarm alarm
profile at both the STU-C and the STU-R.
<registratio
n>
=
The VLAN membership setting.
join: Adds the PVC to the VLAN.
leave: Removes the PVC from the VLAN.
<tag>
=
The VLAN tagging setting.
tag: The specified port(s) accept only incoming Ethernet frames that have a
VLAN tag.
untag: The specified port(s) accept only incoming Ethernet frames that do not
have a VLAN tag.
ras> port pvc vlan 7-5-8/35 23 join untag
span|stuc|stur|*
=
span: Sets the alarm profile for the whole span. This is the entire connection
including any SHDSL regenerators that might be located between the STU-C
(SHDSL Termination Unit - Central) and STU-R (SHDSL Termination Unit -
Remote) end points. An SHDSL regenerator amplifies the SHDSL signal in
order to increase the connection distance.
stuc: Sets the alarm profile at STU-C (SHDSL Termination Unit - Central)
end point
stur: Sets the alarm profile at STU-R (SHDSL Termination Unit - Remote)
end point
*: Sets alarm profile at both STU-C and STU-R
<alarmprofile>
=
The name of an SHDSL alarm profile.
ras> port shdsl alarmprof 6-8 * SESalarm